THICK SENSOR
Enabling of the parameters relevant to
the thick sensor (position sensor)
ON – OFF
STEPPER TIME
Enabling of the stepper functionality on
the welding time
ON – OFF
SERIAL COM.
The operator may choose whether to activate the serial data transmission port and how it is to
be used, connect a printer (232) or connect the control unit to a data supervision network
(485), or not to use this option (OFF).
NET ADDRESS
This parameter indicates the identifying address of the control unit when connected in the
network, activating the aforesaid option.
OUT LOCK/END
This parameter is used to indicate the time for activation of the corresponding output, interlock
(LOCK) or end of cycle (END).
LOW FORCE SQ.
This parameter is used for enabling the low-pressure squeeze function for pneumatic circuit
welders that are equipped with this function. Its enabling adds the SQUEEZE parameter to
the welding program.
FORGE
This parameter is used for enabling the forging for pneumatic circuit welders that are
equipped with this function. Its enabling adds the FORGE DELAY parameter to the work
program.
PROP. VALVE
This parameter is used for enabling the use of a proportional valve for pneumatic circuit
welders that are equipped with this function. Its enabling adds the PRESSURE parameter to
the work program.
If the FORGE parameter is enabled too, then the FORG.PRESS. parameter is added to the
work program.
PRESSURE RATIO
This parameter can be used to select the optimum bar/Volt ratio for the type of proportional
solenoid valve that is to be employed. It works only if the PROP. VALVE parameter is
enabled.
Further pieces of information are described in the paragraph
INTERFACE FOR
PROPORTIONAL VALVE
.
AUTORETAIN
This parameter allows disabling the AUTORETAIN cycle start signal.
On setting the parameter on the OFF value, the working cycle is stopped the moment the
cycle start signal is disabled and does not complete the welding time. This occurs even if the
welding current is in its flowing phase.
The welding time is always completed whenever the value is set to ON.
This function is specifically to be used when the machine works with mechanical devices
instead of pneumatic ones.