TE700 Instruction
Manual
101/128
Power limits
Activate this mode by setting the CONTROL MODE parameter to PW.
Two new parameters will be displayed:
LIM P MIN lower limit on the power supplied during the welding operation
LIM P MAX upper limit on the power supplied during the welding operation
that permit setting limit values on the power supplied during the welding operation.
PROGRAM DATA T1
TOOLS N° 1
WORKING MODE IK
>CONTROL MODE PW
PROGRAM DATA T1
>PAUSE 00
LIM P MIN 010.00KW
LIM P MAX 020.25KW
In power control mode (CONTROL MODE = PW), if the value of the power is higher or lower
than the values set in the foregoing parameters, one of the following messages is displayed:
STOP BAD SPOT MAX T1
POWER [207]
LIMIT LOW
PUSH [///] TO RESET
STOP BAD SPOT MAX T1
POWER [208]
LIMIT HIGH
PUSH [///] TO RESET
Energy limits
Activate this mode by setting the CONTROL MODE parameter to ENE.
Two new parameters will be displayed:
LIM E MIN lower limit of the energy supplied during the welding operation
LIM E MAX upper limit of the energy supplied during the welding operation
that permit setting limit values on the energy supplied during the welding operation.
PROGRAM DATA T1
TOOLS N° 1
WORKING MODE IK
>CONTROL MODE ENE
PROGRAM DATA T1
>PAUSE 00
LIM E MIN 01000J
LIM E MAX 02000J
In control mode of the energy (CONTROL MODE = ENE), if the value of the energy is higher
or lower than the values set in the foregoing parameters, one of the following messages is
displayed:
STOP BAD SPOT MAX T1
ENERGY [209]
LIMIT LOW
PUSH [///] TO RESET
STOP BAD SPOT MAX T1
ENERGY [210]
LIMIT HIGH
PUSH [///] TO RESET
Limits on electrode penetration
Activate this mode by setting the QUALITY-T parameter to IDENT or TH+ID.
Two new parameters will be displayed:
IDENT. MIN lower limit of the electrode penetration at the end of the welding.
IDENT. MAX upper limit of the electrode penetration at the end of the welding.
that permit setting electrode penetration limit values at the end of the welding procedure.