It indicates the number of the present spot. The counter increases when the control unit is in
WELD mode and does not increase when the unit is in NO WELD mode.
INC1 001.0 % 0F 060%
It indicates the present percentage increase of the quantity associated with
stepper
law 1 and
the final increment of the same quantity at the end of the present STEP.
If INC 1 000.0 % OF 000 % is displayed, this means that no quantity is present associated
with
stepper
law 1 or that a percentage increase of 0% has been associated with this quantity.
The value is not updated when the control unit is in NO WELD mode.
INC2 023.1 % OF 030 %
It indicates the present percentage increase of the quantity associated with
stepper
law 2 and
the final increment of the same quantity at the end of the present STEP.
If INC 2 000.0% OF 000 % is displayed, this means that no quantity is present associated
with
stepper
law 2 or that a percentage increase of 0% has been associated with this quantity.
The value is not updated when the control unit is in NO WELD mode.
Use keys and inside this screen to view data relevant to the previously carried out 20
weld spots. The control unit only stores data relevant to spots carried out in WELD mode. The
execution of a weld either in WELD mode or in NO WELD mode entails the display of the data
relevant to the last spot carried out in WELD mode.
Electrodes dressing analysis screen
This screen may be accessed only if the dressing function (optional) is activated on the
control unit.
PRG 005-FE ZN 10-01
SOT 00001
INC DRESS 01%
DRESSING -00500
PRG 005-FE ZN 10-01
005
Indicates the program used to carry out the last weld. The number ranges from 001 to
300. It is displayed both in WELD and NO WELD mode.
FE ZN 10
is the alphanumeric identifier associated with the selected weld program. These are
8 characters that are defined at will by the operator to better identify the weld program. It is
displayed both in WELD and NO WELD mode.
01
is the identifier of the number of the transformer used to carry out the weld or the number
of the tool used. The number ranges from 1 to 4. It is displayed both in WELD and NO WELD
mode.
SPOT 00001
It indicates the number of the present spot. The counter increases when the control unit is in
WELD mode and does not increase when the unit is in NO WELD mode.
INC DRESS 01%
It indicates the percentage increase of the weld parameter inside the present electrodes
dressing STEP. The value does not increase when the unit is in NO WELD mode.