Instruction Manual
ITEM TE700
TECNA
S.p.A.
66/128
2.12 -
FEATURES TE700
-TE700 VER. 1.13--
SETUP MENU
STEPPER MENU
>FEATURES TE700
The TE700 installation menu contains the parameters that describe the complexity and the
typology of the welder on which the control unit works. Access to said menu is protected by
an access code due the importance of these parameters.
ENTER ACCESS CODE
FEATURES MENU
- - - - -
If the operator is not authorized to enter this menu and does not know the access code, the
following message is displayed:
WRONG CODE
TRY AGAIN !
The parameters can be edited only after having typed in the access code.
FEATURES TE700
>SERIAL COM. OFF
NET ADDRESS 01
OUT LOCK/END END
Keep in mind that only skilled personnel are permitted to edit the following
parameters to prevent damage to people or equipment.
PARAMETER
PARAMETER DESCRIPTION
RANGE VALUE
SERIAL COM.
Serial communication
232 – 485 – OFF
NET ADDRESS
Network address
01 – 31
OUT LOCK/END
Output function
END – LOCK
LOW FORCE SQ.
Low force squeeze
ON - OFF
FORGE
Forging
ON – OFF
PROP. VALVE
Proportional valve
ON - OFF
PRESSURE RATIO
Proportional ratio
0.1 – 2.0
AUTORETAIN
Start Autoretain
ON – OFF
START 1-2 NC
Operation of NC inputs
OFF – RIC 7-8 – ON
BIC 1-2 NC
Operation of NC inputs
OFF – RIC 5-6 – ON
SEAM WELD MODE
Spots / seams
ON – OFF
CASCADE MODE
Electric cascade function
ON – OFF
WELD – NO WELD
Operation of weld - no weld external
input
INT – EXT – BOTH
DSP UPG PRESS
Command to update inverter SW
<+>