TECNA
S.p.A.
ITEM
TE700 Instruction
Manual
49/128
CURRENT 2
The value expressed in this parameter indicates the current which the WELD is carried out
with.
This parameter is displayed only in the IK or ENE WORKING MODE. This parameter is
activated through the specific function in the
SETUP MENU.
RO 2
The value expressed in this parameter indicates the current slicing percentage which the
WELD is carried out with.
This parameter is displayed only in the FIX WORKING MODE. This
parameter is activated through the specific function in the
SETUP MENU.
VE 2
The value expressed in this parameter indicates the value of the secondary voltage which the
WELD is carried out with.
This parameter is displayed only in the VEK WORKING MODE.
This parameter is activated through the specific function in the
SETUP MENU.
POWER 2
The value expressed in this parameter indicates the value of the secondary power which the
WELD is carried out with. This parameter is displayed only with WORKING MODE in PWK.
This parameter is activated through the specific function in the
SETUP MENU.
SLOPE DOWN
The current slope down parameter (SLOPE DOWN) is a weld. time that is added at the end of
the welding procedure during which the welding current decreases from the value set in the
adjustment parameter of the WELD or WELD 2 (if present) down to the minimum value
foreseen by the adjustment parameter if the COLD 3 TIME is other than zero whilst if the
COLD 3 TIME is zero and POST-WELD is other than zero, the minimum value will be the
value set for the adjustment parameter in POST WELD.
The downward inclination is calculated automatically by the microprocessor according to the
programmed values. The SLOPE DOWN time is always summed up to the welding time.
This parameter may be activated through the relevant function in the
SETUP MENU
.
COLD 3
The COLD 3 parameter indicates the time that elapses between the WELD time and the
POST-WELD time. This parameter is activated through the specific function in the
SETUP
MENU
.
POST-WELD
The post-weld. time parameter (POST-WELD) describes the duration of a current passage
that may be carried out after the weld. time. This parameter is expressed by four digits since it
can be adjusted with a 1-mS precision. If the parameter is set to 0, the post-weld. will not be
carried out. The post-weld. will be carried out in the adjustment mode set in the working mode
with value equal to that set in the control parameter. This parameter is activated through the
specific function in the
SETUP MENU
.
POST-CURR.
The value expressed in this parameter indicates the current which the POST WELD is carried
out with.
This parameter is displayed only in the IK or ENE WORKING MODE. This parameter
is activated through the specific function in the
SETUP MENU.