TECNA
S.p.A.
ITEM
TE700 Instruction
Manual
2.15
– CHECK INPUT – DIAGNOSTIC TE700
-TE700 VER. 1.13--
FEATURES INVERTER
PROGRAM COPY
>DIAGNOSTIC TE700
This menu displays the status of the inputs of the TE700 weld control unit. It is used to check
the working efficiency of the external devices, connected to the TE700 control unit, required
for using the welder.
DIAGNOSTIC TE700
>START 1 PRG OFF
START1 NC-RIC7 OFF
AUX OFF
The following inputs are mentioned in the list which may be scrolled by means of the
and
keys.
PARAMETER
PARAMETER DESCRIPTION
VALUE
START 1 PRG
It indicates the status of the cycle start signal
ON – OFF
START1 NC-RIC7
It indicates the status of cycle start NC signal or RIC7
ON – OFF
AUX
It indicates the status of the auxiliary signal
ON – OFF
AUX 3
It indicates the status of the auxiliary 3 signal
ON – OFF
DOUBLE STROKE
It indicates the status of the double stroke signal
ON – OFF
START 2 PRG
It indicates the status of the cycle 2 start signal
ON – OFF
START2 NC-RIC8
It indicates the status of cycle start NC signal or RIC8
ON – OFF
TERM/FLUX
It indicates the status of the thermostat signal
ON – OFF
PRG.RECALL 1
It indicates the status of the recall 1 signal
ON – OFF
PRG.RECALL 2
It indicates the status of the recall 2 signal
ON – OFF
PRG.RECALL 3
It indicates the status of the recall 3 signal
ON – OFF
PRG.RECALL 4
It indicates the status of the recall 4 signal
ON – OFF
INVERTER READY
It indicates the status of the READY signal from the inverter unit
ON – OFF
SAFETY START 1
It indicates the status of the signal of safety start 1
ON – OFF
BIC1 NC-RIC5
It indicates the status of the NC signal of two-hand control button 1 or
RIC5
ON – OFF
SAFETY START 2
It indicates the status of the signal of safety start 2
ON – OFF
BIC2 NC-RIC6
It indicates the status of the NC signal of two-hand control button 2 or
RIC6
ON – OFF
(When Code 50200 option is present)
RESET DRESS
It indicates the status of the accomplished electrodes dressing signal
ON – OFF
WELD / NO WELD
It indicates the status of the external weld / no weld signal
ON – OFF
RESET ERROR
It indicates the status of the errors clear signal
ON – OFF
RESET ELECTRODE It indicates the status of the accomplished electrodes change signal
ON – OFF
The input status is represented as enabled (closed input with COM1) by means of the wording
ON, while it is represented as disabled by means of the wording OFF.
77/128