Activate this parameter by setting the CONTROL MODE to RO, otherwise the parameter is
not displayed during the programming phase. The display of this parameter depends on the
configuration of the machine set in the
FEATURES
INVERTER
and
FEATURES TE700
menus
.
LIM RO MAX
This parameter defines a maximum current slicing limit value. Each time a weld is carried out
the control unit checks that the average current slicing held during the welding operation is
less than the value set in this parameter. Otherwise an error condition occurs (see the specific
paragraph).
Activate this parameter by setting the CONTROL MODE to RO, otherwise the parameter is
not displayed during the programming phase. The display of this parameter depends on the
configuration of the machine set in the
FEATURES
INVERTER
and
FEATURES TE700
menus
.
LIM V MIN
This parameter defines a minimum secondary voltage limit value. Each time a weld is carried
out the control unit checks that the secondary voltage during the welding operation is greater
than the value set in this parameter. Otherwise an error condition occurs (see the specific
paragraph).
Activate this parameter by setting the CONTROL MODE to VE, otherwise the parameter is
not displayed during the programming phase. The display of this parameter depends on the
configuration of the machine set in the
FEATURES
INVERTER
and
FEATURES TE700
menus
.
LIM V MAX
This parameter defines a maximum secondary voltage limit value. Each time a weld is carried
out the control unit checks that the secondary voltage during the welding operation is less
than the value set in this parameter. Otherwise an error condition occurs (see the specific
paragraph).
Activate this parameter by setting the CONTROL MODE to VE, otherwise the parameter is
not displayed during the programming phase. The display of this parameter depends on the
configuration of the machine set in the
FEATURES
INVERTER
and
FEATURES TE700
menus
.
LIM P MIN
This parameter defines a minimum power limit value. Each time a weld is carried out the
control unit checks that the power supplied by the welder is greater than the value set in this
parameter. Otherwise an error condition occurs (see the specific paragraph).
Activate this parameter by setting the CONTROL MODE to PW, otherwise the parameter is
not displayed during the programming phase. The display of this parameter depends on the
configuration of the machine set in the
FEATURES
INVERTER
and
FEATURES TE700
menus
.
LIM P MAX
This parameter defines a maximum power limit value. Each time a weld is carried out the
control unit checks that the power supplied by the welder is less than the value set in this
parameter. Otherwise an error condition occurs (see the specific paragraph).
Activate this parameter by setting the CONTROL MODE to PW, otherwise the parameter is
not displayed during the programming phase. The display of this parameter depends on the
configuration of the machine set in the
FEATURES
INVERTER
and
FEATURES TE700
menus
.