TECNA
S.p.A.
ITEM
TE700 Instruction
Manual
53/128
IDENT MAX
This parameter defines an upper limit as concerns the maximum electrodes penetration at the
end of the welding procedure. At the end of the welding operation the measurement of the
penetration value must be less than the set limit. Otherwise an error condition occurs (see the
specific paragraph).
Activate this parameter by setting QUALITY-T. to IDENT or TH+ID, otherwise the parameter
is not displayed during the programming phase. The display of this parameter depends on the
configuration of the machine set in the
FEATURES
INVERTER
and
FEATURES TE700
menus
.
R MIN PRE
This parameter defines a lower limit as concerns the value of the material's initial resistance.
Before starting the welding, the initial resistance value must be greater than the minimum set
value. Otherwise an error condition occurs (see the specific paragraph).
Activate this parameter by setting QUALITY-R. to PRE or PRE+POST, otherwise the
parameter is not displayed during the programming phase. The display of this parameter
depends on the configuration of the machine set in the
FEATURES
INVERTER
and
FEATURES TE700
menus
.
R MAX PRE
This parameter defines an upper limit as concerns the value of the material's initial resistance.
Before starting the welding, the initial resistance value must be less than the maximum set
value. Otherwise an error condition occurs (see the specific paragraph).
Activate this parameter by setting QUALITY-R. to PRE or PRE+POST, otherwise the
parameter is not displayed during the programming phase. The display of this parameter
depends on the configuration of the machine set in the
FEATURES
INVERTER
and
FEATURES TE700
menus
.
R MIN POST
This parameter defines a lower limit as concerns the value of the material's final resistance. At
the end of the welding, the value of the material's final resistance must be greater than the
minimum set limit. Otherwise an error condition occurs (see the specific paragraph).
Activate this parameter by setting QUALITY-R. to POST or PRE+POST, otherwise the
parameter is not displayed during the programming phase. The display of this parameter
depends on the configuration of the machine set in the
FEATURES INVERTER
and
FEATURES TE700
menus
.
R MAX POST
This parameter defines the maximum limit as concerns the value of the material's final
resistance. At the end of the welding, the value of the material's final resistance must be
greater than the maximum set limit. Otherwise an error condition occurs (see specific
paragraph).
Activate this parameter by setting QUALITY-T. to THICK or TH+ID, otherwise the parameter
is not displayed during the programming phase. The display of this parameter depends on the
configuration of the machine set in the
FEATURES INVERTER
and
FEATURES TE700
menus
.