TABLE WITH CONSTANT SECONDARY VOLTAGE OPERATING MODE PARAMETERS
PARAMETER RANGE
VALUE
PROGRAM N.
001 – 300
WORKING MODE
VEK
CONTROL MODE *
NO
QUALITY – T*
OFF
QUALITY – R *
OFF
SQUEEZE 1
0.5 – 99.0 cycles
SQUEEZE
00.0 – 99.0 cycles
PRESSURE
00.5 – 10.0 bar
FORGE DELAY
00 – 99 cycles
FORG.PRESS.
00.5 – 10.0 bar
PRE-WELD
0000 – 1000 mS
PRE-VE
00.20 – 20.00 V
COLD 1
0000 – 1000 mS
SLOPE UP
0000 – 1000 mS
WELD
0001 – 2000 mS
VE
00.20 – 20.00 V
CURR. MAX.
001.00 – 200.00 KA
COLD 2
0000 – 1000 mS
IMPULSE N.
1 – 9
WELD 2
0000 – 1000 mS
VE 2
00.20 – 20.00 V
SLOPE DOWN
0000 – 1000 mS
COLD 3
0000 – 1000 mS
POST-WELD
0000 – 1000 mS
POST-VE
00.20 – 20.00 V
HOLD TIME
00.5 – 99.0 cycles
OFF TIME
00.0 – 99.0 cycles
CONTROL MODE *
CUR
LIM I MIN
000.30 – 200.00 KA
LIM I MAX
000.30 – 200.00 KA
CONTROL MODE *
RO
LIM RO MIN
005.0 – 100.0%
LIM RO MAX
005.0 – 100.0%
CONTROL MODE *
VE
LIM V MIN
00.20 – 20.00 V
LIM V MAX
00.20 – 20.00 V
CONTROL MODE *
PW
LIM P MIN
000.20 - 600.00 KW
LIM P MAX
000.20 – 600.00 KW
CONTROL MODE *
ENE
LIM E MIN
00000 – 60000 J
LIM E MAX
00000 – 60000 J