TECNA
S.p.A.
ITEM
TE700 Instruction
Manual
39/128
THICK. MIN
00.00 – 60.00 mm
THICK MAX
00.00 – 60.00 MM
QUALITY –T *
IDENT
IDENT. MIN
0.000 – 6.000 mm
IDENT. MAX
0.000 – 6.000 mm
QUALITY –T *
TH+ID
THICK. MIN
00.00 – 60.00 mm
THICK MAX
00.00 – 60.00 MM
IDENT. MIN
0.000 – 6.000 mm
IDENT. MAX
0.000 – 6.000 mm
QUALITY –T *
ZERO
QUALITY –R *
PRE
RMIN PRE
0 – 60000uOhm
RMAX PRE
0 – 60000uOhm
QUALITY –R *
POST
RMIN POST
0 – 60000uOhm
RMAX POST
0 – 60000uOhm
QUALITY –R *
PRE+POST
RMIN PRE
0 – 60000uOhm
RMAX PRE
0 – 60000uOhm
RMIN POST
0 – 60000uOhm
RMAX POST
0 – 60000uOhm
QUALITY –R *
ZERO
There are some special conditions:
On setting the OFF TIME to zero, the control unit will work in single cycle.
On setting the PRE-WELD parameter to zero, the pre-welding process will not be carried
out.
On setting the POST-WELD parameter to zero, the post-welding process will not be
carried out.
On setting WELD 2 parameter to zero, WELD 2 will not be carried out.
On setting LIM I MIN and LIM I MAX to the same value, the limits are deactivated.
On setting LIM RO MIN and LIM RO MAX to the same value, the limits are deactivated.
On setting LIM V MIN and LIM V MAX to the same value, the limits are deactivated.
On setting LIM P MIN and LIM P MAX to the same value, the limits are deactivated.
On setting LIM E MIN and LIM E MAX to the same value, the limits are deactivated.
On setting THICK. MIN and THICK. MAX to the same value, the limits are deactivated.
On setting IDENT. MIN and IDENT. MAX to the same value, the limits are deactivated.
On setting RMIN PRE and RMAX PRE to the same value, the limits are deactivated
On setting RMIN POST and RMAX POST to the same value, the limits are deactivated