Instruction Manual
ITEM TE700
TECNA
S.p.A.
16/128
DRESSING – 00500
It indicates the remaining number of weld spots before the need to carry out the electrodes'
dressing or changing operations. The counter does not decrease when the control unit is in
NO WELD mode.
Use keys and inside this screen to view data relevant to the previously carried out 20
weld spots. The control unit only stores data relevant to spots carried out in WELD mode. The
execution of a weld either in WELD mode or in NO WELD mode entails the display of the data
relevant to the last spot carried out in WELD mode.
Quality analysis screen
This screen may be accessed only when the quality control function is enabled in the control
unit by measuring the resistance of the material to be spot welded or by measuring the
thickness of the material in between the electrodes.
PRG 005-FE ZN 10-01
IDENT. 00.000mm
THICK. 00.000mm
R START 0000.0uOhm
PRG 005-FE ZN 10-01
005
Indicates the program used to carry out the last weld. The number ranges from 001 to
300. It is displayed both in WELD and NO WELD mode.
FE ZN 10
is the alphanumeric identifier associated with the selected weld program. These are
8 characters that are defined at will by the operator to better identify the weld program. It is
displayed both in WELD and NO WELD mode.
01
is the identifier of the number of the transformer used to carry out the weld or the number
of the tool used. The number ranges from 1 to 4. It is displayed both in WELD and NO WELD
mode.
IDENT. 00.000MM
It indicates the measurement of the electrode penetration into the material at the end of the
welding procedure.
If this function is disabled, 00.000mm is displayed. The value is updated both in WELD mode
and in NO WELD mode.
THICK. 00.000mm
It indicates the initial thickness of the material to be welded. The measurement is carried out
before the current passage. If this function is not enabled, 00.000mm is displayed.
The value is updated both in WELD mode and in NO WELD mode.
R START 0000.0uOhm
It indicates the initial value of the resistance of the material to be spot welded. The value is
updated only when the control unit is in WELD mode.
Use keys and inside this screen to view data relevant to the previously carried out 20
weld spots. The control unit only stores data relevant to spots carried out in WELD mode. The
execution of a weld either in WELD mode or in NO WELD mode entails the display of the data
relevant to the last spot carried out in WELD mode.