Instruction Manual
ITEM TE700
TECNA
S.p.A.
122/128
MESSAGE
N°
CAUSE
REMEDY
WELD ENERGY
BEFORE T WELD MIN
162
The welding energy set in the control
unit was attained before the minimum
set time.
Reset the error as specified
and check the program to
modify certain parameters
such as ENERGY, POWER
and WELD
WELD ENERGY
NOT REACHED
163
The welding energy set in the control
unit was NOT attained within the max
set time.
Reset the error as specified
and check the program to
modify certain parameters
such as ENERGY, POWER
and WELD
STEPPER
END
164
End of the stepper function.
Reset the error as
specified, perform
maintenance to the
electrodes and reset the
spots counter.
DRESSING
CAPS NEED DRESSING
165
End of a step with electrodes dressing
activated.
Reset the error as specified
and dress the electrodes.
DRESSING
END CAPS LIFE
166
End of electrodes life with electrodes
dressing activated.
Reset the error as specified
and change the electrodes.
STOP
N SPOT MAX
167
The max set number of spots was
attained.
Reset the error as specified
and reset the spots counter.
FAIL ROG COIL
SHORTED OR OPEN
168
With the Rogowsky test activated, a
problem was detected at the
secondary current sensor or its wiring.
Contact service center.
COM FAIL
SPOT DATA LOST
169
Malfunction of the CAN
communication between TE700
control unit and inverter.
Contact service center.
FAIL POS SENS
POS SENSE DISABLED
170
Position sensors initialization error.
Check that the position
sensors are properly wired.
Contact service center.
POS SENSOR
REQUIRED
171
The operator is using a weld program
that entails the presence of the
position sensors but they are not
present.
Check the weld program
used. If the QUALITY-T
function is set, deactivate it.
POS SENSOR
ZERO QUOTE MISSING
172
The QUALITY-T function was
activated in a weld program but the
coordinate zero procedure was not
carried out.
Set the QUALITY-T
parameter to zero and carry
out a welding without any
material in between the
electrodes to define the
ZERO coordinate. Restore
the original value of the
QUALITY-T parameter.