altered by the vibrations induced in the structure. As such, a minimum delay must be set,
which depends on each structure, to carry out the coordinate measurements in a static type
situation.
Proceed as follows to determine the minimum wait time before executing the measurement:
1) Configure the linear position sensor for use.
2) Set the DELAY ID. parameter to zero.
3) Set the WELD QUALITY parameter in the SET UP menu equivalent to T-
ONLY (THICKNESS).
4) Set, in the PROGRAM DATA menu, the QUALITY-T parameter to ZERO in
the program used for welding. Carry out a spot in short circuit to zero the
coordinate (electrodes without material in between).
5) Set, in the PROGRAM DATA menu, the QUALITY-T parameter to IDENT in
the program used for welding.
6) Carry out a spot in short circuit, observe the penetration measurement
supplied on the TE700 control unit display at the end of the welding
procedure. If the value remains equal to zero even after several weld spots
this means that the set delay is correct.
7) If the displayed penetration value does not remain constant on carrying
out several welds, return to the THICKNESS SENSE menu and increase
the DELAY ID. parameter relevant to the position sensor used.
8) Repeat a few weld spots as specified in point 6.