TECNA
S.p.A.
ITEM
TE700 Instruction
Manual
115/128
Progressive spot number
Out-of-limit spot signal
The control unit prints the heading and the value of the parameters of the selected program,
when turned on and each time the key selector is switched from PROGRAM to RUN position.
Data print example during the weld in WORKING MODE = IK:
WELD CONTROL UNIT TE700 REV.1.09
PROG TOOL WELD CURRENT RO ENERGY SPOTS LIMIT
001 1 0200 002.99 034.6 00741 00004 -------
001 1 0200 002.99 034.7 00741 00005 -------
001 1 0200 002.99 034.9 00747 00006 -------
001 1 0200 002.99 034.9 00749 00007 -------
001 1 0200 002.99 035.0 00756 00008 -------
001 1 0200 002.99 035.0 00761 00009 -------
Data print example during the weld in CONTROL MODE = CUR:
WELD CONTROL UNIT TE700 REV.1.13
PROG TOOL WELD CURRENT RO ENERGY SPOTS LIMIT
001 1 0200 002.99 034.6 00741 00004 CUR OK
001 1 0200 002.99 034.7 00741 00005 CUR MIN
(Current lower than MIN limit)
001 1 0200 002.99 034.9 00747 00006 CUR MAX
(Current higher than MAX limit)
001 1 0200 002.99 034.9 00749 00007 CUR OK
001 1 0200 002.99 035.0 00756 00008 CUR OK
001 1 0200 002.99 035.0 00761 00009 CUR OK
Print example of the work program parameters values:
WELD CONTROL UNIT TE700 REV.1.13
PROGRAM N. 001
PRG. NAME
N0 WELD TOOL 1
WORKING MODE IK
CONTROL MODE CUR
SQUEEZE1 01.0~
PRE-WELD 0000mS
PRE CURR 000.30kA
COLD T. 1 0000mS
CURR. SLOPE UP 0000mS
WELD 0200mS
CURRENT 003.00kA
COLD T. 2 0400mS
IMPULSE N. 2
WELD 2 0000mS
CURRENT 2 000.30kA
HOLD 01.0~
PAUSE 00.0~
LIM I MIN 000.31kA
LIM I MAX 004.42kA