Instruction Manual
ITEM TE700
TECNA
S.p.A.
102/128
PROGRAM DATA T1
WORKING MODE IK
CONTROL MODE NO
>QUALITY-T IDENT
PROGRAM DATA T1
>PAUSE 00
IDENT. MIN 1.000mm
IDENT. MAX 1.500mm
In electrode penetration control mode (QUALITY-T = IDENT or TH+ID), if the value of the
penetration is higher or lower than the values set in the foregoing parameters, one of the
following messages is displayed:
STOP BAD SPOT MAX T1
DISPLACEMENT [211]
LIMIT LOW
PUSH [///] TO RESET
STOP BAD SPOT MAX T1
DISPLACEMENT [212]
LIMIT HIGH
PUSH [///] TO RESET
Limits on final resistance of material
Activate this mode by setting the QUALITY-R parameter to POST or PRE+POST.
Two new parameters will be displayed:
RMIN POST lower limit of the resistance at the end of the welding procedure.
RMAX POST upper limit of the resistance at the end of the welding procedure.
that permit setting resistance limit values at the end of the welding procedure.
PROGRAM DATA T1
WORKING MODE IK
CONTROL MODE NO
>QUALITY-R POST
PROGRAM DATA T1
>PAUSE 00
RMIN POST 00100uOhm
RMAX POST 00200uOhm
In final resistance control mode (QUALITY-R = POST or PRE+POST), if the value of the
resistance is higher or lower than the values set in the foregoing parameters, one of the
following messages is displayed:
STOP BAD SPOT MAX T1
RESISTANCE [213]
LIMIT LOW
PUSH [///] TO RESET
STOP BAD SPOT MAX T1
RESISTANCE [214]
LIMIT HIGH
PUSH [///] TO RESET
The operator may set the following limits simultaneously: a limit on the electrical parameters
of the weld (current, voltage, RO, power, energy), the limits on the final resistance of the
welded material (if the spot welder has the electrodes voltage gauge) and the limits on the
electrode penetration at the end of the welding procedure (if the spot welder has the linear
sensor for measuring penetration). All the foregoing settable limits are linked to the STOP
SPOTS parameter. If the parameter equals zero even in the presence of out of limits welds,
the spot welder keeps working but if the parameter is other than zero, the spot welder stops
on reaching the set number of the out of limits welds and indicates the out of limits condition
on the display. If multiple limit conditions occur, they all contribute cumulatively to the
attainment of the number of out of limits spots provided that the out of limits spots occur in
sequence; in this case that which is displayed on reaching the max number of out of limits
spots refers to the last quantity that did not fall within the set limits.
The following limits may be activated simultaneously with the aforementioned limits.
Specifically, the limit on the initial resistance of the material to be welded can be activated
only if the spot welder has the electrodes voltage gauge and the limit on the initial thickness of
the material to be welded can be activated only if the linear position sensor is installed on the