Explanations of Menus
3-34
8. Change Unit
You can use engineering units instead of the physical units to be written in the
VERT_UNITS line of the header file. The coefficient (SLOPE value) is accord-
ingly converted and written in the header file. To specify a different unit, click
Change Unit
, choose a desired channel from the list in the dialog box that
appears, and enter values and the unit to complete the equation at the bottom of
the box.
Example:
If you record a signal from an anemometer that outputs 10 V at an wind velocity
of 50 m/sec (0 V at 0 m/sec) and you choose 10 V for the input range, the unit
name in VERT_UNITS will be “V”, and the SLOPE value will be 10 / 25000 =
0.0004. Then, if you enter as shown below in the Change Unit dialog box, the unit
name in VERT_UNITS will be “m/s”, and the SLOPE value will be 0.002.
▼
The unit names must be within four characters.
▼
The units displayed on the left of the waveform
graphs will be also changed to the units speci-
fied by this setting.
▼
This setting is not saved.
▼
You cannot change the units for the micro-
phone input amps and thermocouple input
amps.
▼
This .gxs file is different from a .prm file. The
.prm file stores the parameter settings only.
▼
Loading may take some time depending on the
contents of the file to be loaded.
■
Save Setting
Saves the settings from
System
,
Misc
, and
Params
in the
Setup
menu. The set-
tings are saved in a .gxs file. It is recommended that you save the settings for an
unexpected accident.
■
Load Setting
Loads the .gxs file. Before loading, insert the same medium that was used when the
gxs file was saved into the same slot. The settings in this file are set in the GX-1
main unit when the file is read.
You can select a format for the coefficient values to be written in the SLOPE line
of the header file.
Decimal Format:
Written in a decimal number
Ex) 12.3456789
Exponential Format: Written in a exponential number
Ex) 1.2345E+01
Содержание GX-1
Страница 5: ...iv...
Страница 6: ...Introduction 1 1 Overview 1 3 Features 1 4 About TAFFmat 1 6 Precautions 1 6 Name of Each Part 1 7...
Страница 7: ...1 2...
Страница 15: ...1 10...
Страница 17: ...2 2...
Страница 27: ...2 12...
Страница 28: ...GX Navi 3 1...
Страница 29: ...3 2...
Страница 47: ...3 20...
Страница 67: ...3 40...
Страница 68: ...Technical Information 4 1...
Страница 69: ...4 2...
Страница 79: ...Specifications 4 12 External Dimensions Unit mm 300 85 200...
Страница 80: ...4 13...
Страница 81: ...4 14...
Страница 116: ...Appendix 5 1 In Case of Trouble 5 3 Index 5 4 Supplied Accessories 5 5 Separately Purchasable Options 5 5...
Страница 117: ...5 2...
Страница 121: ...5 6...