Basic Operations
3-19
■
Recording Without a PC
You can record to recording media (such as AIT or an MO
disk) using the handy remote controller ER-GXRC only, with-
out connecting to a PC. In the upper right of the GX Navi
System
window, select
ON/OFF
in
Stand Alone / Auto
Eject
.
When ON/OFF is Selected
In this mode, you can control GX-1 recording by using the ER-
GXRC only (Stand Alone is ON). Control is also possible from
GX Navi; though, in such a case, the media is not ejected when
GX Navi terminates (Auto Eject is OFF).
•
Before recording, you must use GX Navi to select the
recording media and set the various parameters.
•
When using the ER-GXRC (without using GX Navi) to
eject the media, in the STOP mode press the eject button on
the drive. Make sure that the BUSY lamp on the drive is
extinguished when you do this. When using GX Navi to
control operations, use GX Navi to eject the media.
•
When AIT recording is stopped or paused, catalog informa-
tion is recorded. This is information about all the files on the
AIT tape, so writing this information takes about 1 minute.
Therefore, if the next recording starts quickly, the recording
data is buffered in internal memory. In this mode, if you
repeatedly stop and then start recording, the internal buffer
will continue to be consumed and the internal buffer might
become full during recording. In such a case, recording will
stop automatically.
•
Even if you forget to eject the AIT and turn off the power
after a new AIT recording, catalog information is already
recorded.
•
Before calibrating the microphone input amp AR-GXMC or
zero-balancing the strain input amp AR-GXST, you must
first turn on the power. If you are recording without a PC in
a system that uses a microphone input amp or a strain input
amp, start recording as follows. First connect the PC and use
GX Navi to perform calibration or zero balancing. Next, ter-
minate GX Navi, disconnect the PC (with the power left on)
from GX-1, and then start recording.
When OFF/ON is Selected
In this mode, you cannot control GX-1 recording by using the
ER-GXRC only (Stand Alone is OFF). You must connect a PC
and use GX Navi. When GX Navi terminates, the medium is
ejected automatically (Auto Eject is ON).
•
Ejection of the media is controlled from GX Navi, and the
eject button on the drive is unusable.
•
The catalog information for AIT recording is recorded in a
batch at ejection.
•
If you forget to eject the AIT and turn off the power after a
new AIT recording, catalog information is not recorded.
There is, however, a restoration function for catalog informa-
tion. Restoration might take a long time: perhaps more than
20 or 30 minutes.
■
When Recording to a PC Card
When you record to a PC card, ejection requires manual opera-
tion. So whether you select ON/OFF or OFF/ON, the operation
is the same. Also, when you record using the handy remote con-
troller without connecting a PC, the GX-1 selects the card slot
for recording regardless of the GX Navi setting. When two
cards are inserted, data is recorded to the card in the upper slot.
When one card is inserted, data is recorded to that card.
Содержание GX-1
Страница 5: ...iv...
Страница 6: ...Introduction 1 1 Overview 1 3 Features 1 4 About TAFFmat 1 6 Precautions 1 6 Name of Each Part 1 7...
Страница 7: ...1 2...
Страница 15: ...1 10...
Страница 17: ...2 2...
Страница 27: ...2 12...
Страница 28: ...GX Navi 3 1...
Страница 29: ...3 2...
Страница 47: ...3 20...
Страница 67: ...3 40...
Страница 68: ...Technical Information 4 1...
Страница 69: ...4 2...
Страница 79: ...Specifications 4 12 External Dimensions Unit mm 300 85 200...
Страница 80: ...4 13...
Страница 81: ...4 14...
Страница 116: ...Appendix 5 1 In Case of Trouble 5 3 Index 5 4 Supplied Accessories 5 5 Separately Purchasable Options 5 5...
Страница 117: ...5 2...
Страница 121: ...5 6...