SVAN 971 User Manual
20
For each power source, there is a different view presented in the
Battery
window of the
Instrument
list.
When the instrument is powered from internal batteries,
the
“Battery”
icon is presented on the top line
of the display. When voltage of the batteries is too low for reliable measurements, the icon is red or
during attempt to switch the instrument on, the
Low Battery!
message occurs on the display for
2 seconds and the instrument switches off by itself. The fully charged set of 4 batteries ensures more
than 12 hours of continuous operation of the instrument (with
Dim
LCD switched on). The battery
condition can be checked with the
Battery
function. It is also presented continuously on the top line of
the display by means of the
“
battery
”
icon.
When there is a connection to the USB interface (
USB Device
socket is connected by the SC 156 cable
to a PC), the
“Computer”
icon is presented on the top of the display and in the
Battery
window, there
is the
USB Power: Voltage: 5.00V
message.
Note: In the case when
“Battery” icon is red, it is strongly recommended to use USB
interface as soon as possible to ensure reliable operation. If no suitable external power source
is provided the instrument will be switched off automatically
after a short time!
Prolonging
the internal source of the instrument’s power can be achieved by means of the LCD screen
Dim Mode
. The settings of power saver function (
Dim Mode
) may be selected in the
Screen Set.
window (
path: <Menu> / Display / Screen Set.)
.
3.3 G
ETTING STARTED
Turning the instrument on
To switch the power on, press the
<Shift>
and
<Start/Stop>
keys simultaneously. The instrument goes
through the self-test routine (in this time the
manufacturer's logo and the name of the instrument is
displayed) and then it enters the basic SPL view mode.
Starting measurements
To start a measurement, press the
<Start/Stop>
key. Results of the
measurement are displayed in the view mode that was active before turning the
instrument off. As an example, screen with one profile mode is presented.
One profile mode is always available for most Functions of the instrument. The measurement results can
also be presented in other display modes, which you may control - switch them on or off and adjust to
your needs.
Setting up measurement parameters
The instrument as sold has default settings which you may change, but always
return to them with the use of the
Factory Settings
option in the
Auxiliary Setup
menu.
Next chapters of the manual will describe in detail what each parameter means
and how to change the instrument settings.
Main default settings
With default settings, the instrument has a
Simple
user interface and is configured
as a Sound Level Meter (
Measurement Function: Level Meter
) to measure
sound pressure level by three virtual meters, so called profiles, with 1 second
delay from the
<Start>
key pressure, infinite integration time (
Integration Period:
Inf
), linear Leq integration (
LEQ Integration: Linear
), compensation of
microphone internal noise (
Compensation Filter: Microphone
), active logging
of the selected results (
Lpeak
,
Lmax
,
Lmin
and
Leq
) with 1 second step for all
Содержание SVAN 971
Страница 98: ...SVAN 971 User Manual 98 ...
Страница 154: ...SVAN 971 User Manual Appendixes 154 1000 Hz 1250 Hz 400 Hz 500 Hz 630 Hz 800 Hz ...
Страница 155: ...SVAN 971 User Manual Appendixes 155 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Страница 156: ...SVAN 971 User Manual Appendixes 156 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Страница 157: ...SVAN 971 User Manual Appendixes 157 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Страница 169: ...SVAN 971 User Manual Appendixes 169 2 0 kHz 1 1 octave filter 1 0 kHz 1 1 octave filter 500 Hz 1 1 octave filter ...
Страница 170: ...SVAN 971 User Manual Appendixes 170 250 Hz 1 1 octave filter 125 Hz 1 1 octave filter 63 0 Hz 1 1 octave filter ...
Страница 177: ...SVAN 971 User Manual Appendixes 177 B filter Class 1 according to the IEC 651 B filter characteristics ...
Страница 206: ...SVAN 971 User Manual Appendixes 206 400 Hz 500 Hz 630 Hz 800 Hz 1000 Hz 1250 Hz ...
Страница 207: ...SVAN 971 User Manual Appendixes 207 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Страница 208: ...SVAN 971 User Manual Appendixes 208 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Страница 209: ...SVAN 971 User Manual Appendixes 209 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Страница 220: ...SVAN 971 User Manual Appendixes 220 ...