SVAN 971 User Manual
– Appendixes
146
Linear operating ranges for LEQ measurements
with Diffuse Filter
Table C.1.4.
Linear operating range
for the “Diffuse” filter: “LOW” for the sinusoidal signal and microphone
sensitivity 35 mV/Pa
[dB]
L
AS/F
L
BS/F
L
CS/F
L
ZS/F
L
AeqT
L
BeqT
L
CeqT
L
AE
L
Cpeak
(t
int
= 2 s)
from
to
from
to
from
to
from
to
from
to
from
to
from
to
from
to
from
to
31,5 Hz
26
83
26
106
26
120
32
123
26
83
26
106
26
120
29
86
50
123
500
Hz
26
119
26
122
26
123
32
123
26
119
26
122
26
123
29
122
50
126
1 kHz
26
123
26
123
26
123
32
123
26
123
26
123
26
123
29
126
50
126
4 kHz
26
124
26
122
26
122
32
123
26
124
26
122
26
122
29
127
50
126
8 kHz
26
122
26
120
26
120
32
123
26
122
26
120
26
120
29
126
50
123
12.5
kHz
26
118
26
117
26
117
32
123
26
118
26
117
26
117
29
121
50
120
Table C.1.5.
Linear operating range
for the “Diffuse” filter: „HIGH“ (primary level range) for the sinusoidal
signal and microphone sensitivity 35 mV/Pa
[dB]
L
AS/F
L
BS/F
L
CS/F
L
ZS/F
L
AeqT
L
BeqT
L
CeqT
L
AE
L
Cpeak
(t
int
= 2 s)
from
to
from
to
from
to
from
to
from
to
from
to
from
to
from
to
from
to
31,5 Hz
36
97
36
120
36
134
42
137
36
97
36
120
36
134
39
100
60
137
500
Hz
36
133
36
136
36
137
42
137
36
133
36
136
36
137
39
136
60
140
1 kHz
36
137
36
137
36
137
42
137
36
137
36
137
36
137
39
140
60
140
4 kHz
36
138
36
136
36
136
42
137
36
138
36
136
36
136
39
141
60
139
8 kHz
36
136
36
134
36
134
42
137
36
136
36
134
36
134
39
139
60
137
12.5
kHz
36
132
36
131
36
131
42
137
36
132
36
131
36
131
39
136
60
134
Linear operating ranges
with the SA 22 windscreen
See C1.2
RMS detector
•
Digital
“True RMS“ with Peak detection,
•
Resolution
0.1 dB
•
Range
327.7 dB
•
Crest Factor
unlimited (for signals in 20 kHz band).
Overload detector
The instrument has the built-in overload detectors. The overload in the measurement channel (in its analogue
part) and the overload of the analogue /
digital converter are both detected. The “overload” indication is when
the input signal amplitude
is 0.5 dB above
the declared “Peak measurement range”
Underrange detector
The instrument has the built-
in underrange detector. The “underrange” indication appears when the minimum
value of the RMS detector output goes below the specified lower linear operating range
Содержание SVAN 971
Страница 98: ...SVAN 971 User Manual 98 ...
Страница 154: ...SVAN 971 User Manual Appendixes 154 1000 Hz 1250 Hz 400 Hz 500 Hz 630 Hz 800 Hz ...
Страница 155: ...SVAN 971 User Manual Appendixes 155 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Страница 156: ...SVAN 971 User Manual Appendixes 156 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Страница 157: ...SVAN 971 User Manual Appendixes 157 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Страница 169: ...SVAN 971 User Manual Appendixes 169 2 0 kHz 1 1 octave filter 1 0 kHz 1 1 octave filter 500 Hz 1 1 octave filter ...
Страница 170: ...SVAN 971 User Manual Appendixes 170 250 Hz 1 1 octave filter 125 Hz 1 1 octave filter 63 0 Hz 1 1 octave filter ...
Страница 177: ...SVAN 971 User Manual Appendixes 177 B filter Class 1 according to the IEC 651 B filter characteristics ...
Страница 206: ...SVAN 971 User Manual Appendixes 206 400 Hz 500 Hz 630 Hz 800 Hz 1000 Hz 1250 Hz ...
Страница 207: ...SVAN 971 User Manual Appendixes 207 1600 Hz 2000 Hz 2240 Hz 2500 Hz 2800 Hz 3150 Hz ...
Страница 208: ...SVAN 971 User Manual Appendixes 208 3550 Hz 4000 Hz 4500 Hz 5000 Hz 5600 Hz 6300 Hz ...
Страница 209: ...SVAN 971 User Manual Appendixes 209 7100 Hz 8000 Hz 8500 Hz 9000 Hz 9500 Hz 10000 Hz ...
Страница 220: ...SVAN 971 User Manual Appendixes 220 ...