Air Conditioning System: Automatic Type 7B-82
6) Measure output voltage variation while temperature
control actuator is operated from “MAX COOL”
position (B) to “MAX HOT” position (A) as following
specification.
If measure voltage is out of specification or does not
vary linearly as the shown in graph, check related
wire circuit and HVAC control module. If wire circuits
and HVAC control module are OK, go to next step.
Temperature control actuator output voltage
0.48 – 4.53V (linear variation as following graph)
7) Set temperature selector of HVAC control module to
“MAX HOT” position with ignition switch turned ON,
and make sure if the position of actuator lever is
“MAX HOT” position (A).
8) Turn ignition switch to OFF position, and then
disconnect connector from temperature control
actuator.
9) Measure resistance between terminal “1” and “2”.
Temperature control actuator resistance between
terminal “1” and “2” (MAX HOT position)
(Reference value)
Approx. 0.45 k
Ω
at 25
°
C (77
°
F)
10) Connect connector to temperature control actuator.
11) Set temperature selector of HVAC control module to
“MAX COOL” position with ignition switch turned ON,
and make sure if the position of actuator lever is
“MAX COOL” position (B).
12) Turn ignition switch to OFF position, and then
disconnect connector from temperature control
actuator.
13) Measure resistance between terminal “1” and “2”.
Temperature control actuator resistance between
terminal “1” and “2” (MAX COOL position)
(Reference value)
Approx. 4.3 k
Ω
at 25
°
C (77
°
F)
If measure resistance is out of specification, replace the
actuator with new one.
[A]: MAX HOT
[B]: MAX COOL
[C]: Actuator lever position
1
2
3
4
5
6
6
M
5
3
2
1
A
B
4.53
0.48
5.00
(V)
[C]
[A]
[B]
I7RW01722017-03
1
2
3
4
5
6
6
M
5
3
2
1
A
I7RW01722020-02
1
2
3
4
5
6
6
M
5
3
2
1
B
I7RW01722021-02
Содержание 2006 SX4
Страница 2: ......
Страница 6: ......
Страница 22: ...00 15 Precautions...
Страница 38: ...0B 7 Maintenance and Lubrication...
Страница 378: ...1K 6 Exhaust System...
Страница 848: ...6C 46 Power Assisted Steering System...
Страница 954: ...7B 89 Air Conditioning System Automatic Type...
Страница 1086: ...8B 121 Air Bag System...
Страница 1381: ...Paint Coatings 9L 7 I5RW0C9C0005 01 A Apply sealant 1 Hole...
Страница 1382: ...9L 8 Paint Coatings I5RW0C9C0006 01 A Apply sealant covering flange end...
Страница 1386: ...9L 12 Paint Coatings I5RW0A9C0010 01 A Apply rust proof wax hot wax 50 m or more B Never fill up drain holes with rust proof wax...
Страница 1476: ...Prepared by 1st Ed Feb 2007...
Страница 1477: ...31 0 mm 99500 80J00 01E SERVICE MANUAL VOL 1 OF 2 99500 80J00 01E SERVICE MANUAL VOLUME 1 OF 2 RW420...
Страница 1478: ...28 0 mm 99500 80J00 01E SERVICE MANUAL VOL 2 OF 2 99500 80J00 01E SERVICE MANUAL VOLUME 2 OF 2 RW420...