1F-7 Engine Cooling System:
Thermostat Removal and Installation
S6RW0C1606007
Removal
1) Drain coolant.
2) Disconnect radiator outlet hose from thermostat cap
(1).
3) Remove thermostat cap (1) from water pump (2).
4) Remove thermostat from water pump (2).
Installation
Reverse removal procedure for installation noting the
following points.
• When positioning thermostat (1) on water pump case,
be sure to position it so that air bleed valve (2) comes
at match mark (3) and into the recession of water
pump case.
• Use new O-ring when installing.
• Refill cooling system referring to Step 9) to 17) of
“Cooling System Flush and Refill”.
• Verify that there is no coolant leakage at each
connection.
Thermostat Inspection
S6RW0C1606008
• Make sure that air bleed valve (1) of thermostat is
clean.
• Check to make sure that valve seat (2) is free from
foreign matters which would prevent valve from
seating tight.
• Check thermostat seal (3) for breakage, deterioration
or any other damage.
• Check thermostatic movement of wax pellet as
follows:
a. Immerse thermostat (1) in water, and heat water
gradually.
b. Check that valve starts to open at specific
temperature.
Temperature at which valve begins to open
80 – 84
°
C (176 – 183
°
F)
Temperature at which valve become fully open
95 – 97
°
C (203 – 206
°
F)
Valve lift
More than 8 mm (0.31 in.) at 95
°
C (203
°
F)
If valve starts to open at a temperature substantially
below or above specific temperature, thermostat unit
should be replaced with a new one. Such a unit, if
reused, will bring about overcooling or overheating
tendency.
I5JB0A161009-01
I2RH01160010-01
2. Thermometer
3. Heater
I3RM0A160008-01
I2RH01160012-01
Содержание 2006 SX4
Страница 2: ......
Страница 6: ......
Страница 22: ...00 15 Precautions...
Страница 38: ...0B 7 Maintenance and Lubrication...
Страница 378: ...1K 6 Exhaust System...
Страница 848: ...6C 46 Power Assisted Steering System...
Страница 954: ...7B 89 Air Conditioning System Automatic Type...
Страница 1086: ...8B 121 Air Bag System...
Страница 1381: ...Paint Coatings 9L 7 I5RW0C9C0005 01 A Apply sealant 1 Hole...
Страница 1382: ...9L 8 Paint Coatings I5RW0C9C0006 01 A Apply sealant covering flange end...
Страница 1386: ...9L 12 Paint Coatings I5RW0A9C0010 01 A Apply rust proof wax hot wax 50 m or more B Never fill up drain holes with rust proof wax...
Страница 1476: ...Prepared by 1st Ed Feb 2007...
Страница 1477: ...31 0 mm 99500 80J00 01E SERVICE MANUAL VOL 1 OF 2 99500 80J00 01E SERVICE MANUAL VOLUME 1 OF 2 RW420...
Страница 1478: ...28 0 mm 99500 80J00 01E SERVICE MANUAL VOL 2 OF 2 99500 80J00 01E SERVICE MANUAL VOLUME 2 OF 2 RW420...