7B-51 Air Conditioning System: Automatic Type
DTC Table
S6RW0C7224006
CAUTION
!
Be sure to perform “Air Conditioning System Check” before starting diagnosis.
NOTE
• History DTC is such DTC which HVAC control module saves in its memory when it detects current
DTC for 60 seconds or more continuously.
• DTC B1504, B1541, B1546, B1570 and B1571 are displayed as a current DTC only when a current
malfunction is detected.
• When HVAC control module detects DTC B1513 and B1514, both current and history DTCs are
displayed at the same time.
DTC No.
(displayed
on SUZUKI
scan tool)
Detection item
DTC (indicated on
HVAC control
module)
Condition when trouble detected (DTC is
determined when following condition detected)
“A/C”
indicator
light
Indicated
by “REC”
indicator
light
Indicated
by “FRE”
indicator
light
)
B1502
Inside Air
Temperature
Sensor Circuit
Malfunction
2
1
Signal voltage of inside air temperature sensor is
higher than specification.
Flashed
2
2
Signal voltage of inside air temperature sensor is
lower than specification.
Flashed
)
B1503
Evaporator
Temperature
Sensor Circuit
Malfunction
3
1
Signal voltage of evaporator temperature sensor is
higher than specification.
Flashed
3
2
Signal voltage of evaporator temperature sensor is
lower than specification.
Flashed
)
B1504
Sun load Sensor
Circuit
Malfunction
4
1
• Signal voltage of sun load sensor is higher than
specification.
• Without sunlight.
—
4
2
Signal voltage of sun load sensor is lower than
specification.
Flashed
)
B1511
Temperature
Control Actuator
(Position Sensor)
and/or Its Circuit
Malfunction
6
1
Signal voltage of position sensor included in
temperature control actuator is higher than
specification.
Flashed
6
2
Signal voltage of position sensor included in
temperature control actuator is lower than
specification.
Flashed
)
B1512
Air Flow Control
Actuator
(Position Sensor)
and/or Its Circuit
Malfunction
7
1
Signal voltage of position sensor included in airflow
control actuator is higher than specification.
Flashed
7
2
Signal voltage of position sensor included in airflow
control actuator is lower than specification.
Flashed
)
B1513
Temperature
Control Actuator
(Motor) and/or Its
Circuit
Malfunction
6
3
Motor of temperature control actuator is not
operated more than specified time.
Flashed
)
B1514
Air Flow Control
Actuator (Motor)
and/or Its Circuit
Malfunction
7
3
Motor of air flow control actuator is not operated
more than specified time.
Flashed
)
B1520
Temperature
Selector
Malfunction
15
1
Signal voltage of temperature selector in HVAC
control module is higher than specification.
Flashed
15
2
Signal voltage of temperature selector in HVAC
control module is lower than specification.
Flashed
Содержание 2006 SX4
Страница 2: ......
Страница 6: ......
Страница 22: ...00 15 Precautions...
Страница 38: ...0B 7 Maintenance and Lubrication...
Страница 378: ...1K 6 Exhaust System...
Страница 848: ...6C 46 Power Assisted Steering System...
Страница 954: ...7B 89 Air Conditioning System Automatic Type...
Страница 1086: ...8B 121 Air Bag System...
Страница 1381: ...Paint Coatings 9L 7 I5RW0C9C0005 01 A Apply sealant 1 Hole...
Страница 1382: ...9L 8 Paint Coatings I5RW0C9C0006 01 A Apply sealant covering flange end...
Страница 1386: ...9L 12 Paint Coatings I5RW0A9C0010 01 A Apply rust proof wax hot wax 50 m or more B Never fill up drain holes with rust proof wax...
Страница 1476: ...Prepared by 1st Ed Feb 2007...
Страница 1477: ...31 0 mm 99500 80J00 01E SERVICE MANUAL VOL 1 OF 2 99500 80J00 01E SERVICE MANUAL VOLUME 1 OF 2 RW420...
Страница 1478: ...28 0 mm 99500 80J00 01E SERVICE MANUAL VOL 2 OF 2 99500 80J00 01E SERVICE MANUAL VOLUME 2 OF 2 RW420...