7B-13 Air Conditioning System: Manual Type
A/C System Symptom Diagnosis
S6RW0C7214004
Condition
Possible cause
Correction / Reference Item
No cool air comes out (A/
C compressor does not
operate)
No refrigerant
Perform recovery, evacuation and charge
referring to “Operation Procedure for
Refrigerant Charge”.
Fuse blown
Check related fuses, and then check for short
circuit to ground.
A/C switch faulty
Check A/C switch referring to “A/C Switch
Inspection”.
Blower speed selector faulty
Check blower speed selector referring to
“Blower Speed Selector Inspection in Section
7A”.
Evaporator temperature sensor faulty
Check evaporator temperature sensor
referring to “Evaporator Temperature Sensor
Inspection”.
A/C refrigerant pressure sensor faulty
Check A/C refrigerant pressure sensor
referring to “A/C Refrigerant Pressure Sensor
and Its Circuit Inspection”.
Wiring or grounding faulty
Repair as necessary.
ECM faulty
Check ECM referring to “A/C System
Inspection at ECM”.
Magnet clutch faulty
Check magnet clutch referring to “Magnet
Clutch Inspection”.
Compressor drive belt loosened or
broken
Adjust or replace drive belt.
Compressor faulty
Check compressor.
Compressor relay faulty
Check compressor relay referring to “A/C
System Relay Inspection”.
BCM faulty
Check BCM referring to “Inspection of BCM
and Its Circuits in Section 10B”.
No cool air comes out
(radiator cooling fan
motor does not operate)
Fuse blown
Check related fuses, and then check for short
circuit to ground.
Wiring or grounding faulty
Repair as necessary.
Condenser cooling fan relay faulty
Check condenser cooling fan motor relay
referring to “A/C System Relay Inspection”.
Condenser cooling fan motor faulty
Check condenser cooling fan motor referring to
“Condenser Cooling Fan Inspection”.
ECM faulty
Check ECM referring to “A/C System
Inspection at ECM”.
No cool air comes out
(blower motor does not
operate)
Fuse blown
Check related fuses, and then check for short
circuit to ground.
Blower motor relay faulty
Check blower motor relay referring to “Blower
Motor Relay Inspection in Section 7A”.
Blower motor resistor faulty
Check blower motor resistor referring to
“Blower Motor Resistor Inspection in Section
7A”.
Blower speed selector faulty
Check blower speed selector referring to
“Blower Speed Selector Inspection in Section
7A”.
Wiring or grounding faulty
Repair as necessary.
Blower motor faulty
Check blower motor referring to “Blower Motor
Inspection in Section 7A”.
Содержание 2006 SX4
Страница 2: ......
Страница 6: ......
Страница 22: ...00 15 Precautions...
Страница 38: ...0B 7 Maintenance and Lubrication...
Страница 378: ...1K 6 Exhaust System...
Страница 848: ...6C 46 Power Assisted Steering System...
Страница 954: ...7B 89 Air Conditioning System Automatic Type...
Страница 1086: ...8B 121 Air Bag System...
Страница 1381: ...Paint Coatings 9L 7 I5RW0C9C0005 01 A Apply sealant 1 Hole...
Страница 1382: ...9L 8 Paint Coatings I5RW0C9C0006 01 A Apply sealant covering flange end...
Страница 1386: ...9L 12 Paint Coatings I5RW0A9C0010 01 A Apply rust proof wax hot wax 50 m or more B Never fill up drain holes with rust proof wax...
Страница 1476: ...Prepared by 1st Ed Feb 2007...
Страница 1477: ...31 0 mm 99500 80J00 01E SERVICE MANUAL VOL 1 OF 2 99500 80J00 01E SERVICE MANUAL VOLUME 1 OF 2 RW420...
Страница 1478: ...28 0 mm 99500 80J00 01E SERVICE MANUAL VOL 2 OF 2 99500 80J00 01E SERVICE MANUAL VOLUME 2 OF 2 RW420...