4
EN
4. Technical data
- 59 -
951-170-218-EN
Version 06
Technical data, Table 3
(2 of 2)
Universal data Key data / indicator
Designation
UFD10-1-XXX000
UFD20-1-XXX000
Connection for aerosol line
Plug connector for plastic tube 12x1
Automatic lubricant refill
Connection for suction line
Plug connector for plastic tube Pa11/12 plastic tube 10x1.5
Connection for return / reservoir drainage
Plug connector for plastic tube Pa11/12 plastic tube 10x1.5
Connection for aerosol line
Plug connector for plastic tube 12x1
Bypass valve, 20 bar
G 1/2"
Design variant
UFD10-1-10X000 UFD10-1-20X000 UFD10-1-11X000 UFD10-1-21X000
UFD20-1-10X000
Field bus protocol type
PROFIBUS
PROFINET
PROFIBUS
PROFINET
PROFIBUS
Bypass control
-
-
•
•
-
Number of aerosol generators
1
1
1
1
2
Recommended air pressure
6 bar/87 psi
6 bar/87 psi
10 bar/145 psi
10 bar/145 psi
6 bar/87 psi
Total weight, filled with lubricant
30 kg/66 lb
33 kg/66 lb
36 kg/79 lb
36 kg/79 lb
40 kg/88 lb
Protective measures that must be taken for operation according to the intended use in machinery:
o
"Functional Extra Low Voltage," "Protective Extra Low Voltage" (PELV)
o
Disconnect the MQL system for insulation and voltage inspection according to EN 60204-1