Quick Start Guide

Self-contained Smart Camera with User-Friendly Vision Manager Software

This guide is designed to help you set up and install the VE Series Smart Camera. For complete information on programming, performance,

troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at 

www.bannerengineering.com

. Search for p/n 191666

to view the Instruction Manual. Use of this document assumes familiarity with pertinent industry standards and practices. More details are

available in the online help.

WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or

death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety

applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.

CAUTION: Electrostatic Discharge
Avoid the damage that electrostatic discharge (ESD) can cause to the Sensor.
Always use a proven method for preventing electrostatic discharge when installing a lens or attaching a cable.

CAUTION: Hot Surface
Use caution when handling the camera.
 The surface of the camera may be hot during operation and immediately

after use.

Models

Model1

Resolution

VE200G1A

WVGA, 752 × 480 pixels grayscale

VE201G1A

1.3 MP, 1280 × 1024 pixels grayscale

VE202G1A

2 MP, 1600 × 1200 pixels grayscale

Features

1

2

3

4

5

7

6

8

9

Figure 1. Sensor Features

1. Display
2. Buttons
3. Pass/Fail indicator (green/red)
4. Ready/Trigger indicator (green/amber)
5. Power/Error indicator (green/red)
6. Ethernet indicator (amber), not shown
7. Ethernet connection
8. Light connection
9. Power, Discrete I/O connection

1 Model VE202G2A, 2 MP, 1600 × 1200 grayscale with 4-pin D-code M12 Ethernet connection is also available.

VE Series Smart Camera

 

 

Original Document

191667 Rev. C

27 October 2016

191667

Содержание VE200G1A

Страница 1: ...on can cause either an energized or de energized sensor output condition CAUTION Electrostatic Discharge Avoid the damage that electrostatic discharge ESD can cause to the Sensor Always use a proven m...

Страница 2: ...asurement and flaw analysis Run time editing allows you to make changes to an inspection while the sensor is running reducing costly downtime Vision Manager also includes a full software emulator allo...

Страница 3: ...cator 1 Connect the Ethernet cable to the sensor 3 and to the computer or Ethernet switch 2 Connect the power discrete I O cable to the sensor 1 and the leads to the appropriate locations See Table 1...

Страница 4: ...the sensor Important Administrative rights are required to install the Vision Manager software 1 Download the latest version of the software from www bannerengineering com 2 Navigate to and open the d...

Страница 5: ...255 255 255 0 2 Open Vision Manager from the desktop or the Start menu The Sensor Neighborhood tab displays and lists the available sensors 3 From Sensor Neighborhood click to connect to the desired...

Страница 6: ...the region of interest ROI for the tool for the selected inspection Figure 9 Sensor Screen Acquire a Good Image The sensor needs to capture a good image of each part to ensure that it correctly passe...

Страница 7: ...oups of connected light or dark pixels within the ROI and designates them as blobs Binary Large Objects After blobs are found they can be characterized by size and shape Edge Detects and counts transi...

Страница 8: ...rete I O settings Figure 10 Discrete I O For more details see the Instruction Manual Sensor Display The LCD display on the top of the sensor provides access to view or change several settings without...

Страница 9: ...menu and return to the parent menu Leave the current menu and return to the Home Screen from any menu Important Pressing Escape discards any unsaved changes In the Sensor Menu a return arrow in the up...

Страница 10: ...INK SUBNET GATEWAY STATUS IP PSELECT TRIGGER INPUT MAC MAX SPD By NUM OUTPUT FW VER BOOT NAME MODEL HOUR SERIAL SLEEP VIEW Ethernet Menu Product Change by Slot No Bit Representation of Input Output St...

Страница 11: ...ices are secure free from bugs viruses interruption errors theft or destruction If the exclusions for implied warranties do not apply to you any implied warranties are limited to 60 days from the date...

Отзывы: