3
- 39 -
951-170-218-EN
Version 06
EN
3. Overview, functional description
View
A
View
B
1
10
4
5
12
7
13
9
6
11
8
2
3
2
10
AIR
System 1
System 1
AEROSOL
System 1
PARAMETER
7
STR
2
1
3 4 5 6
8
900
1500
1300
1100
1200
1000
1400
700
800
600
500
400
300
100
200
0
4
6
0
30
60
2
90
120
10
8
4
60
30
2
0
6
8
10
120
90
UFD10-1-100000
Bypass Valve
Power
24VDC
RS232
Ball Valve
IN OUT
B
A
14
UFD10 with PROFIBUS, Fig. 9
Item Description
1
Control cabinet housing
2 Connections for aerosol lines
(for max. of three spindles)
3
Screw plug for manual filling
4 Fill level indicator
5
Pressure gauge for internal reservoir
pressure
6
Pressure gauge for air inlet pressure
7
Compressed air connection
(main air valve)
8
Lubricant drain valve
9
Sight glass for display panel of
control unit
10 Safety valve
11
Fine filter for compressed air
12
Oil filter
13
PROFIBUS interface
14 Ground connection