EN
4. Technical data
- 58 -
951-170-218-EN
Version 06
4. Technical data
Technical data, Table 3
(1 of 2)
Universal data Key data / indicator
Designation
UFD10-1-XXX000
UFD20-1-XXX000
Mounting position
Vertical, connections downward
Reservoir capacity, utilizable
1.2 liter
Permissible operating pressure/ambient
temperature
+ 10°C to +40°C
Lubricant
See approval list
Lubricant output per outlet
1
)
3 to 400 ml/h
Operating pressure, air
4 to 10 bar
Air consumption per aerosol generator
1
)
10 to 500 Nl/min
Purity of
permissible compressed air
At least quality class 5 according to ISO 8573-1:
Max. particle size/density 40 µm/10 mg/m³; Pressure dew point 7°C; Water content max.
7,800 mg/m³; Residual oil content max. 25 mg/m³.
Electrical data per control unit
Rated voltage
Power consumption with filling pump
Power consumption without filling pump
24 ± 20% VDC
Max. 3.5 A
Max. 1.0 A
Protection class according to DIN EN 60529
IP 54
Weight with full aerosol generator
30 kg
40 kg
Reservoir capacity, utilizable
1.2 l
1.2 l each
1) Depends on back pressure (diameter of the tool’s cooling ducts, lubricant, etc.)
4.1 General technical data