8
EN
8. Communication with machine control unit
- 101 -
951-170-218-EN
Version 06
Input word assignments when using a process image with analog value transmission, Table 12
Input words
Value/signal
Value range
Unit
Explanation
Word
6
5
4 3 2 1 0
Rela-
tive
address
12 10 8 6 4 2 0
Aerosol density
1
)
0 ... 1000
Relative value, transmitted from aerosol monitor to
MQL system
Air low rate
0-600
Nl/min
Approximate value determined from data available in
MQL system
Aerosol low rate
1
)
0-65535
Dimensionless estimation of aerosol low rate
Oil ill level
0-150
%
Result resulting from evaluation of
discrete
or analog
values from ill level sensor
Inlet pressure
0-100
0.1 bar Pressure applied to MQL system
Internal reservoir pressure
0-100
0.1 bar Prevailing pressure in aerosol generator
Cooling duct cross-section
of tool
0-100
0.1mm
Equivalent cooling duct diameter relative to a cali-
bration tool with deined geometry
1) Only when using an AM1000 aerosol monitor