User Manual
EM303A General Purpose Inverter
82
Use the buttons and switches correctly by following the mode illustrated in the
above diagrams of EM303A 3-wire sequences, otherwise, malfunctions may
occur.
No.
Function
Range
Unit
Default
Type
F0-06
Regular Speed
Setting Mode
0
:
Primary numeric frequency
1
:
VP
2
:
VS
3
:
IS
4
:
Not used
5
:
K3*VS+K4*IS
6
:
K3*VS+K5*VF
7
:
K4*IS+K6*IF
8
:
MAX{K3*VS,K5*VF}
9
:
MAX{K4*IS,K6*IF}
10:K1*VP+K2*(K3*VS+K4*IS+
K5*VF+K6*IF-K8*5V)
0
〇
F0-06
For
selecting the source of regular speed setting signal.
F0-06=0
Primary numeric frequency setting mode is defined by the value of F0-07.
F0-06=1
Setting frequency is set by VP keypad potentiometer.
F0-06=2
Setting frequency is set by the voltage of analog terminal VS.
F0-06=3
Setting frequency is set by the current of analog terminal IS.
F0-06=4
Not used
F0-06=5
Setting frequency is set by: K3*VS+K4*IS (Input signals VS and IS)
F0-06=6
Setting frequency is set by:
K3*VS+K5*VF (Input voltage signals VS and VF)
F0-06=7
Setting frequency is set by: K4*IS+K6*IF (Input current signals IS and IF)
F0-06=8
Setting frequency is set by the greater value between K3*VS and K5*VF
(Inputs of 2 terminals)
F0-06=9
Setting frequency is set by the greater value between K4*IS and K6*IF (Inputs
of 2 terminals)
F0-06=10
Setting frequency is set by:
K1*VP+K2*(K3*VS+K4*IS+K5*VF+K6*IF-K8*5V) (All input signals)
★
The combination of analog voltage signal and analog current signal can be
considered as that the current signal linearly switched to voltage signal of
0-10V first, and then calculate.
1. The default of analog voltage input VS, VF is 0
~
10V.
2. The default of analog current input is 4
~
20mA.
3. K1
~
K8 are analog signal gains which can be set by F1-22
~
F1-29.