User Manual
EM303A General Purpose Inverter
57
F5-13 Torque
Direction
0: Positive Torque
1:Negative Torque
0
●
F5-14
Upper Limit Frequency Limiting
of Torque Control
0: Upper Limit Frequency
1: VS* Upper Limit Frequency
2: IS*Upper Limit Frequency
3: VF*Upper Limit Frequency
4: IF*Upper Limit Frequency
0
〇
F5-15
Preset Torque Current 1
0.00~150.00
%
10.00
●
F5-16
Preset Torque Current 2
0.00~150.00
%
20.00
●
F5-17
Preset Torque Current 3
0.00~150.00
%
30.00
●
F5-18
Preset Torque Current 4
0.00~150.00
%
70.00
●
F5-19
Preset Torque Current 5
0.00~150.00
%
80.00
●
F5-20
Preset Torque Current 6
0.00~150.00
%
90.00
●
F5-21
Preset Torque Current 7
0.00~150.00
%
100.00
●
F5-22 Positive/Negative
Torque
Control
0: Positive/Negative Torque
Permitted
1: Negative Torque Prohibited
0
〇
F5-23
Positive/Negative Torque
Deadband
0.00~600.00 S
0.00
〇
F5-24
Torque Current Gain TP1
0.00~10.00
%
0.60
●
F5-25
Torque Current Integration TTi1
0.000~30.000
S
0.020
●
F5-26
Excitation Current Input
0.00~200.00
%
100.00
●
F5-27
Excitation Proportion Gain MP1
0.00~10.00
%
0.20
●
F5-28
Excitation Integration Time
MTi1
0.000~10.000 S
0.200
●
F5-29
Excitation Boost Gain Kd
0.00~400.00
%
100.00
●
F5-30 Excitation
Current
Forming
Time
0.00
~
10.00 S
0.10
〇
F5-31 Not
Used