User Manual
EM303A General Purpose Inverter
71
6.2.14
Group Fb: Advanced Parameters of PID
No.
Function
Range
Unit
Default
Type
Fb-00 PID
Setting Mode
0: General mode 1: Special mode
0
〇
Fb-01 Special
Mode
0: Program operation
1: Stepping mode 0
2: Stepping mode 1
3: Stepping mode 2
4: Stepping mode 3
5: Stepping mode 4
0
〇
Fb-02
PID UP/DOWN
Rate
0.00~10.00 V/S
1.00
●
Fb-03
PID Regulator
Output
0: PID Regulator output
1:PID Regulator Feedforward
output
0
〇
Fb-04
PID Integration
Control
0: Active after PID starts deadband
time
1:Active after PID outputs soft start
time
0
〇
Fb-05
Feedforward Gain
Soft Start
0: Within PID output deadband time,
linear to feedforward input gain
1: Feedforward input gain
0
〇
Fb-06
PID Output Soft
Start
0: Within PID output soft-start time,
linear to PID output gain
1: PID output gain
0
〇
Fb-07
Feedforward Input
Mode
0: GFK*VS
1: GFK*IS
2: Not Used
3: GFK*+10V
4:
GFK* Primary numeric frequency setting
0
〇
Fb-08
Feedforward Gain
Upper Limit
100.00~300.00 %
200.00
●
Fb-09
Feedforward Initial
Gain GFK
0.00~Feedforward input gain upper
limit
% 40.00
●
Fb-10
PID Output
Deadband Time
0.00~100.00 S
0.00
●
Fb-11 PID
Soft-start
Time
0.00~120.00
S
5.00
●
Fb-12
PID Upper/Lower
Limits Output
Control
Ones place: PID upper limit output control
0: Enabled when PID soft-start time is up
1: Enabled when PID output deadband is up
2: Enabled after operation
3: Enabled after power is on
Tens place: PID lower limit output control
0: Enabled when PID soft-start time is up
1: Enabled when PID outputs deadband is up
2: Enabled after operation
3: Enabled after power is on
00
〇
Fb-13
Lower Limit
Control Voltage
0.00~10.00 V
0.50
●
Fb-14
Upper Limit
Control Voltage
0.00~10.00 V
9.50
●
Fb-15
PID Continuous
Circulation Times
1~10000
1
●
Fb-16
~
Fb-19 Not Used
Fb-20
Preset PID Setting 1
0.00~10.00
V
1.00
●
Fb-21
Preset PID Setting 2
0.00~10.00
V
2.00
●
Fb-22
Preset PID Setting 3
0.00~10.00
V
3.00
●
Fb-23
Preset PID Setting 4
0.00~10.00
V
5.00
●
Fb-24
Preset PID Setting 5
0.00~10.00
V
8.00
●
Fb-25
Preset PID Setting 6
0.00~10.00
V
9.00
●
Fb-26
Preset PID Setting 7
0.00~10.00
V
10.00
●
Fb-27
~
Fb-31 Not Used
Содержание EM303A-011G/015P-3CB
Страница 15: ...User Manual EM303A General Purpose Inverter 15 Figure 1 1 Speed Setting Modes...
Страница 16: ...User Manual EM303A General Purpose Inverter 16 Figure 1 2 Torque Input Modes...
Страница 23: ...User Manual EM303A General Purpose Inverter 23 Figure 2 4 Disassemble the Keypad Figure 2 5 Assemble the Keypad...