User Manual
EM303A General Purpose Inverter
62
F6-08 Operation
Time
T1 0.0~6000.0
S/min
30.0
●
F6-09 Operation
Time
T2 0.0~6000.0
S/min
30.0
●
F6-10 Operation
Time
T3 0.0~6000.0
S/min
30.0
●
F6-11 Operation
Time
T4 0.0~6000.0
S/min
30.0
●
F6-12 Operation
Time
T5 0.0~6000.0
S/min
30.0
●
F6-13 Operation
Time
T6 0.0~6000.0
S/min
30.0
●
F6-14 Operation
Time
T7 0.0~6000.0
S/min
30.0
●
F6-15
Speed Cycling
Times
1~10000
1
●
F6-16
Skip Frequency
Point1
0.00~600.00/0.0~6000.0 Hz
600.00
●
F6-17
Skip Range 1
0.00~20.00/0.0~20.0
0.00/0.00: Disabled
Hz 0.00
●
F6-18
Skip Frequency
Point 2
0.00~600.00/0.0~6000.0 Hz
600.00
●
F6-19
Skip Range 2
0.00~20.00/0.0~20.0
0.00/0.0: Disabled
Hz 0.00
●
F6-20
Skip Frequency
Point 3
0.00~600.00/0.0~6000.0 Hz
600.00
●
F6-21
Skip Range 3
0.00~20.00/0.0~20.0
0.00/0.0: Disabled
Hz 0.00
●
F6-22~ F6-23 Not used
F6-24
Wobbulation
Operation Mode
Ones place: Wobbulation operation
control
0:Auto-operation
1:Terminal Control
Tens place: Wobbulation input mode
0:Wobbulation operation started after
the mid-point reached
1:Start wobbulation operation when its
preset time is up
0
〇
F6-25
Preset Wobbulation
Frequency
0.00~Fmax/0.0~Fmax Hz
0.00
●
F6-26
Preset Wobbulation
Time
0.00~600.00 S
0.00
●
F6-27
Upper Limit
Frequency of
Wobbulation
0.00~Fmax/0.0~Fmax Hz
40.00
●
F6-28
Lower Limit
Frequency of
Wobbulation
0.00~Fmax/0.0~Fmax Hz
20.00
●
F6-29
Jump Frequency of
Wobbulation
0.00~Fmax/0.0~Fmax Hz
5.00
●
F6-30
Rising Time of
Wobbulation
0.00~600.00 S/min
0.00
●
F6-31
Dropping Time of
Wobbulation
0.00~600.00 S/min
5.00
●