User Manual
EM303A General Purpose Inverter
68
Thousands place
:
Process PID Output mode options
0: PID output
1: VS* PID output
2: VF* PID output
3: IS* PID output
4: IF* PID output
5: Auxiliary frequency* PID output
F9-09
Detecting Frequency
at Zero Speed
0.00
~
50.00/0.0
~
50.0 Hz
0.00
〇
F9-10
Detecting Output
Delay at Zero Speed
0.00
~
600.00 S
1.00
〇
F9-11
Frequency Reach
Signal FAR
0.00
~
50.00/0.0
~
50.0 Hz
2.50
〇
F9-12
FDT1 Increasing
Threshold
0.00
~
Fmax /0.0
~
Fmax Hz
30.00
〇
F9-13
FDT1 Decreasing
Threshold
0.00
~
Fmax /0.0
~
Fmax Hz
30.00
〇
F9-14
FDT2 Increasing
Threshold
0.00
~
Fmax /0.0
~
Fmax Hz
30.00
〇
F9-15
FDT2 Decreasing
Threshold
0.00
~
Fmax /0.0
~
Fmax Hz
30.00
〇
F9-16
Not Used
F9-17
Power Failure Stop
Control Options
0: Disabled, not stop at power failure
1: Enabled, stop at running
0
〇
F9-18~F9-20 Not Used
F9-21
Deceleration Time 0
at Power Failure
0.00
~
10.00 S
0.50
〇
F9-22
Deceleration Time 1
at Power Failure
0.00
~
10.00 S
1.50
〇
F9-23
Stop at Power
Failure
10
~
30000 mS
100
〇
F9-24
Start Delay Time
After Power-on
0.00
~
10.00
(The time for inverter to wait for the
initial operation after power-on)
S 1.00
〇
F9-25
Not Used
F9-26
Magnetic Field
Compensation
Coefficient
0.00~200.00 %
0.00
●
F9-27
Oscillation
Suppression Gain
0~20000
0
●
F9-28
Frequency Droop
Control
0.00
~
60.00/0.0
~
60.0 Hz
0.00
〇
F9-29
Iqs Filter Time
0.00
~
10.00 S
0.00
〇
F9-30
Undervoltage
Detection Scaling
0.00~100.00
(
Udc_e
)
%
74.48
〇
F9-31
Undervoltage
Detection Time
0.00~30.00 S
0.50
〇