User Manual
EM303A General Purpose Inverter
118
C0-20
Running Time of
Present Section of
Program Operation
In program operation, the unit of running time at
present operation section is up to the ten
thousand’s place of F6-00.
532 S/min
C0-21
Output Power
Output power calculated by inverter
533
kW
C0-22 PID
Input
Present PID setting voltage value(Controlled by
F4-00)
534 V
C0-23
PID Calculation
Feedback
Present PID feedback voltage value(Controlled by
F4-02)
535 V
C0-24
Torque Current Input
I
q
*
Present torque current input setting value
536
%
C0-25
Torque Current
Feedback I
q
Present output torque current value
537
%
C0-26 Input
Terminal
Status
X7 X6 X5
X4
X3
X2
X1
538
0 0 0 0 0 0 0
X1 is the LSB. (Monitoring the logic status of
external input terminals)
C0-27 Output
Terminal
Status
R1 Y2 Y1
539
0 0 0
Y1 is the LSB. (Monitoring the logic status of
output terminals)
C0-28
VS Input Monitoring
0~10000
540
C0-29
IS Input Monitoring
0~10000
541
C0-30
VF Input Monitoring
0~10000
542
C0-31
IF Input Monitoring
0~10000
543
The displayed rotational speed of motor can be set when monitoring the frequency.
Remarks:
See
EM303A Technical Manual
for the description of parameters in Group F6~F9,
FA, Fb, FC, Fd and FE.