User Manual
EM303A General Purpose Inverter
69
6.2.13
Group FA: Advanced Parameters of Vector Control
No.
Function
Range
Unit
Default
Type
FA-00
Torque Current Setting
Mode
Ones place:
Primary torque setting mode
0: Regular torque setting mode
1: Special torque setting mode
2: Process PID torque setting mode
Tens place:
Integrated torque setting mode
0: Primary torque setting mode
1: Auxiliary torque setting mode
2: Primary torque setting mode +
Auxiliary torque setting mode
Hundreds place:
Auxiliary positive/negative torque
options
0: Positive torque
1: Negative torque
000
〇
FA-01 Special
Mode
0: Program operation
1: Stepping mode 0
2: Stepping mode 1
3: Stepping mode 2
4: Stepping mode 3
5: Stepping mode 4
0
〇
FA-02
Auxiliary Torque
Current Setting
0: Auxiliary Numeric Torque
Current Setting
1
:
VP
2
:
VS
3
:
IS
4
:
VF
5
:
IF
6
:
Not Used
7
:
K1*VP+K2*(K3*VS+K4*IS+
K5*VF+K6*IF-K8*5V)
0
〇
FA-03
Auxiliary Numeric
Torque Current
0.00~150.00 %
0.00
●
FA-04 UP/DOWN
Torque
Rate
0.00~100.00
%/S 1.00
●
FA-05 Torque
Cycling
Times 1~10000
1
〇