User Manual
EM303A General Purpose Inverter
111
No.
Function
Range
Unit
Default
Type
F4-18
If parameters change with
inverter’s working status
0: Unchanged
1: Changed
1
〇
F4-19
Parameters Setting Display
0
~
831
0
●
F4-18=0
When setting parameters, press RUN/JOG button on keypad, the one which
remains unchanged is the monitoring parameter. For example, set
F0-07=50Hz, and press JOG key, the setting value F0-07 displays as 50Hz,
then it shows monitoring parameter of JOG.
F4-18=1
When setting parameters, press RUN/JOG button on keypad, the present
display changes as the monitoring parameter.
F4-19
For
setting the parameter displayed on keypad, when inverter does not run in
parameter setting status. For example: when inverter stops, the parameter
displayed on keypad. The setting value is corresponding to the value in Group
C0.
No.
Function
Range
Unit
Default
Type
F4-20
Parameters displayed in
the 1
st
row in operation
0
~
831 512
●
F4-21
Parameters displayed in
the 2
nd
row in operation
0
~
831 514
●
F4-22
Parameters displayed in
the 3
rd
row in operation
0
~
831 524
●
F4-23
Parameters displayed in
the 4
th
row in operation
0
~
831 525
●
F4-24
Parameters displayed in
the 1
st
row at stop
0
~
831 512
●
F4-25
Parameters displayed in
the 2
nd
row at stop
0
~
831 514
●
F4-26
Parameters displayed in
the 3
rd
row at stop
0
~
831 524
●
F4-27
Parameters displayed in
the 4
th
row at stop
0
~
831 528
●
Selecting the parameters need to be displayed in running and at stop
1. Default selection displays C0-00, C0-02, C0-12, C0-13, and C0-16.
2. See
EM303A Technical Manual
for the number and setting method of relevant
codes.