Appendix
A.1 Ordering Information and Accessories
SIPROTEC, 7SJ61, Manual
C53000-G1140-C210-1, Release date 02.2008
372
1)
only for non-sensitive ground current transformer if 7th digit = 1, 5, 7
2)
for isolated/compensated networks, only for sensitive ground current transformer if 7th digit = 2, 6.
Measuring/Fault Recording
Position
13
With fault recording
1
With fault recording, average values, min/max values
3
Functions
Position
14 and
15
Description
ANSI No.
Description
F A
Basic Elements (included
in all versions)
—
Control
50/51
Time overcurrent protection phase 50-1, 50-2, 50-3, 51, reverse in-
terlocking
50N/51N
Ground fault protection ground 50N-1, 50N-2,
50N-3, 51-N
50N/51N
Insensitive time overcurrent protection ground via SGFD function;
50Ns-1, 50Ns-2, 51Ns
50/50N
Flexible protection functions (parameters from current): additive
overcurrent time protection elements 50-4
49
Overload protection (with 2 time constants)
46
Negative Sequence Protection 46-1, 46-2, 46-TOC
37
Undercurrent monitoring
50BF
Breaker Failure Protection
74TC
Trip Circuit Monitoring
—
Cold-load pickup (dynamic setting changes) 50C-1, 50C-2, 50NC-
1, 50NC-2, 51NC
—
Inrush restraint
86
Lock out
IEF
—
Intermittent ground fault
P A
50Ns/51Ns
87N
Sensitive ground fault detection
High-impedance ground fault differential protection
F B
IEF
50Ns/51Ns
—
87N
Sens. ground fault detection
Intermittent ground fault
High-impedance ground fault differential protection
P B
motor
IEF
50Ns/51Ns
—
87N
48/14
66/86
51M
Sens. ground fault detection
Intermittent ground fault
High-impedance ground fault differential protection
Motor starting supervision, locked rotor
Restart inhibit
Load jam detection in motors, motor statistics
motor
50Ns/51Ns
87N
48/14
66/86
51M
Sens. ground fault detection
High-impedance ground fault differential protection
Motor starting supervision, locked rotor
Restart inhibit
Load jam detection in motors, motor statistics
motor
48/14
66/86
51M
Motor starting supervision, locked rotor
Restart inhibit
Load jam detection in motors, motor statistics
H A
IEF = Intermittent ground (earth) fault protection
Содержание SIPROTEC 7SJ61
Страница 368: ...Technical Data 4 22 Dimensions SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 368 ...
Страница 436: ...Appendix A 11 Measured Values SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 436 ...
Страница 438: ...Literature SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 438 ...
Страница 450: ...Glossary SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 450 ...
Страница 454: ...Index SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 454 ...