Diagnosis / faults and alarms
10.2 Diagnosis
Drive converter cabinet units
410
Operating Instructions, 07/07, A5E00288214A
Customer Terminal Block TM31 (-A60)
Table 10-2 Description of the LEDs on the TM31
LED
Color
State
Description
---
OFF
The electronics power supply is missing or lies outside permissible
tolerance range.
Green
Steady light
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
Orange
Steady light
DRIVE-CLiQ communication is being established.
Red
Steady light
At least one fault is pending on this component.
Note:
LED is driven irrespective of the corresponding messages being
reconfigured.
0.5 Hz flashing
light
Firmware is being downloaded.
Green / red
2 Hz flashing
light
Firmware download is complete. Waiting for POWER ON.
RDY
Green orange
or
red orange
2 Hz flashing
light
Detection of the components via LED is activated (p0154).
Note:
Both options depend on the LED status when module recognition is
activated via p0154 = 1.