Operation
6.8 PROFINET IO
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
245
Definition: Real Time (RT) and determinism
Real time means that a system processes external events over a defined period.
Determinism means that a system responds in a predictable manner (deterministically).
In industrial networks, both of these requirements are important. PROFINET meets these
requirements. PROFINET is implemented as a deterministic real time network as follows:
●
Transmission of time-critical data takes place at guaranteed time intervals. To achieve
this, PROFINET provides an optimized communication channel for real time
communication: Real Time (RT).
●
An exact prediction of the time at which the data transfer takes place is possible.
●
Problem-free communication using other standard protocols is guaranteed within the
same network.
Definition: Isochronous real time communication (IRT)
Isochronous Real Time Ethernet: Real time properties of PROFINET IO where IRT
telegrams are transmitted deterministically via planned communication paths in a defined
sequence to achieve the best possible synchronism and performance. This is also known as
time-scheduled communications whereby knowledge about the network structure is utilized.
IRT requires special network components that support planned data transfer.
When the transfer procedure is implemented in the ERTEC ASICs (Enhanced Real-Time
Ethernet Controller), this results in cycle times of at least. 500 μs and a jitter accuracy of less
than 1 μs.
5HVHUYHGUDQJH
0LQLPXPZLGWK
HJPVF\FOH
&\FOLFVFKHGXOHG
FRPPXQLFDWLRQ
6SRQWDQHRXVFRPPXQLFDWLRQ
0RQLWRUHGOLPLW
0RQLWRUHGOLPLW
Figure 6-43 Broadband distribution/reservation, PROFINET IO IRT
Note
When operating S7-300 stations with SINAMICS drives, presently only communications via
PROFINET IO with RT are possible.
Содержание SINAMICS S150
Страница 2: ......
Страница 6: ...Preface Drive converter cabinet units 6 Operating Instructions 07 07 A5E00288214A ...
Страница 14: ...Table of contents Drive converter cabinet units 14 Operating Instructions 07 07 A5E00288214A ...
Страница 28: ...Device overview 2 5 Type plate Drive converter cabinet units 28 Operating Instructions 07 07 A5E00288214A ...
Страница 519: ......
Страница 520: ...Siemens AG Automation and Drives Large Drives P O Box 4743 90025 NÜRNBERG GERMANY www ad siemens com A5E00288214A ...