4.9.5
Default setting of the interfaces
Default setting 1: "Conveyor technology with 2 fixed frequencies"
$FWXDOVSHHGYDOXH
$FNQRZOHGJHIDXOW
212))FORFNZLVH
212))FRXQWHUFORFNZLVH
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
:DUQLQJ
)DXOW
$2
',
',
',
',
',
'2
'2
DO 0: p0730, DO 1: p0731
AO 0: p0771[0]
DI 0: r0722.0, …, DI 5: r0722.5
Fixed speed setpoint 3: p1003, fixed speed setpoint 4: p1004, fixed speed setpoint active: r1024
Speed setpoint (main setpoint): p1070[0] = 1024
DI 4 and DI 5 = high: The inverter adds both fixed speed setpoints
Designation in the BOP-2: coN 2 SP
Default setting 2: "Conveyor systems with Basic Safety"
$FNQRZOHGJHIDXOW
212))ZLWKIL[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
5HVHUYHGI¾UDVDIHW\IXQFWLRQ
$FWXDOVSHHGYDOXH
:DUQLQJ
)DXOW
$2
',
',
',
',
',
'2
'2
DO 0: p0730, DO 1: p0731
AO 0: p0771[0]
DI 0: r0722.0, …, DI 5: r0722.5
Fixed speed setpoint 1: p1001, fixed speed setpoint 2: p1002, fixed speed setpoint active: r1024
Speed setpoint (main setpoint): p1070[0] = 1024
DI 0 and DI 1 = high: The inverter adds both fixed speed setpoints.
Designation in the BOP-2: coN SAFE
Installing
4.9 Connecting the interfaces for the inverter control
SINAMICS G120C converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF
91