CAUTION
Damage to cables in the Communications and Power Interface
The Terminal Housing has two sets of terminals which are supported on two posts. The
terminals are secured when the Control Module (CM) is screwed into place.
If any cables or wires are routed behind the terminal posts, the downward pressure from the
terminal post clamps has the potential to damage any wire or cable routed behind the terminal
support posts.
• Do not route any cables or wires behind the terminal posts.
WARNING
Unexpected movement of the motor after a PLC power-cycle
The converter has the potential to start running after a power-cycle of the controlling PLC, if an
ON command was present prior to the power-cycle of the PLC.
• Ensure that the converter runs only when it is appropriate of your application.
NOTICE
Converter must not be used as a step or ledge
The converter has not been designed to support a substantial weight. Should substantial
weight be placed on the converter it could result in severe damage to the equipment.
• Don't use the converter as a step or a ledge.
Note
Diagrams and illustrations
In some of the diagrams and illustrations throughout this section, the colour of components or
cables have been selected to make them more visible and do not necessarily reflect the real
colour of the component or cable. In some illustrations, components have been removed to
enhance the clarity of what is being described.
Note
Use only Non-Drive End (NDE) motor configurations
The SINAMICS G110M has been designed to be used in conjunction with NDE motors. Do not use
standard motor terminal box mountings with the SINAMICS G110M systems.
Installation
4.2 System Installation
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL