8.10
Quick Stop function
Overview
The Quick Stop function enables a load on a conveyor system to be detected and if Quick Stop
is enabled, stop the load on the conveyor section.
The load on the conveyor section moves towards a dedicated sensor, as shown in the figure
below.
&RQYH\RUVHFWLRQ
3DFNDJH
6HQVRU
6HQVRU
'LUHFWLRQRIWUDYHO
Figure 8-25
Conveyor example 1
The front edge of the load is detected by the sensor, which initiates the Quick Stop function.
&RQYH\RUVHFWLRQ
3DFNDJH
6HQVRU
6HQVRU
'LUHFWLRQRIWUDYHO
Figure 8-26
Conveyor example 2
The load is then slowed down and stopped.
&RQYH\RUVHFWLRQ
3DFNDJH
6HQVRU
6HQVRU
'LUHFWLRQRIWUDYHO
Figure 8-27
Conveyor example 3
There are two sensors on the conveyor section, so that the Quick Stop function can stop the
conveyor section in either direction when a load is detected.
Advanced commissioning
8.10 Quick Stop function
Distributed converter for SIMOGEAR geared motors
224
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL