7HOHJUDP
7HOHJUDPOHQJWKIRUWKHUHFHLYHGDWD
7HOHJUDPOHQJWKIRUWKHWUDQVPLWGDWD
67:
=6:
3=' 3=' 3=' 3=' 3=' 3=' 3=' 3=' 3=' 3=' 3=' 3=' 3=' 3='
Unassigned interconnection and length
Table 8-23
Abbreviations
Abbreviation
Explanation
Abbreviation
Explanation
PZD
Process data
PKW
Parameter channel
STW
Control word
MIST_GLATT
Actual smoothed torque
ZSW
Status word
PIST_GLATT
Actual smoothed active power
NSOLL_A
Speed setpoint
M_LIM
Torque limiting value
NIST_A
Speed actual value
FAULT_CODE
Fault code
NIST_A_GLATT
Smoothed actual speed value WARN_CODE
Alarm code
IAIST_GLATT
Smoothed current actual val‐
ue
MELD_NAMUR
Message according to the VIK-NA‐
MUR definition
Function description
Control word 1 (STW1)
Bit Significance
Explanation
Signal inter‐
connection
in the con‐
verter
Telegram 20
All other tele‐
grams
0
0 = OFF1
The motor brakes with the ramp-down time
p1121 of the ramp-function generator. The con‐
verter switches off the motor at standstill.
p0840[0] =
r2090.0
0 → 1 = ON
The converter goes into the "ready" state. If, in
addition bit 3 = 1, then the converter switches
on the motor.
1
0 = OFF2
Switch off the motor immediately, the motor
then coasts down to a standstill.
p0844[0] =
r2090.1
1 = No OFF2
The motor can be switched on (ON command).
2
0 = Quick stop (OFF3)
Quick stop: The motor brakes to a standstill with
the OFF3 ramp-down time p1135.
p0848[0] =
r2090.2
1 = No quick stop (OFF3)
The motor can be switched on (ON command).
3
0 = Inhibit operation
Immediately switch-off motor (cancel pulses). p0852[0] =
r2090.3
1 = Enable operation
Switch-on motor (pulses can be enabled).
4
0 = Disable RFG
The converter immediately sets its ramp-func‐
tion generator output to 0.
p1140[0] =
r2090.4
1 = Do not disable RFG
The ramp-function generator can be enabled.
Advanced commissioning
8.6 Drive control via PROFIBUS or PROFINET
Distributed converter for SIMOGEAR geared motors
184
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
Содержание SINAMICS G110M
Страница 2: ......
Страница 426: ...Index Distributed converter for SIMOGEAR geared motors 424 Operating Instructions 10 2020 FW V4 7 SP13 A5E31298649B AL ...
Страница 427: ......