Article No.
6SL3517-…
…1BE14-3AM0
Cross section of line and motor cable
1 … 2.5 mm
2
18 … 14
AWG
Tightening torque for line and motor cable
0.5 Nm / 4 lbf in
Weight
2.1 kg
Table 11-3
PM240M, Frame Sizes B, Class A filter, 3 AC 380 V … 480 V
Article No. - Filtered
6SL3517-…
…1BE16-3AM0
…1BE17-7AM0
…1BE21-0AM0
Rated / LO power
Rated / LO input current
Rated / LO Output current
2.2 kW
5.3 A
5.9 A
3 kW
6.9 A
7.7 A
4 kW
8.0 A
10.2 A
HO power
HO input current
HO output current
2.2 kW
5.3 A
5.6 A
3 KW
6.9 A
7.3 A
4 kW
8.0 A
8.8 A
Fuse
20 A, Class J, CC
20 A, Class J, CC
20 A, Class J, CC
Power losses
0.153 kW
0.073 kW
0.091 kW
Required cooling air flow
24 l/s
24 l/s
24 l/s
Cross section of line and motor cable
1 … 2.5 mm
2
18 … 14
AWG
1 … 2.5 mm
2
18 … 14
AWG
1 … 2.5 mm
2
18 … 14
AWG
Tightening torque for line and motor cable
0.5 Nm / 4 lbf in
0.5 Nm / 4 lbf in
0.5 Nm / 4 lbf in
Weight
3.4 kg
3.4 kg
3.4 kg
Minimum required resistance for the braking resistors
For each Power Module rating there is a minimum resistance required for the braking resistors
associated with the specific power modules, please refer to the tables above for further details.
Table 11-4
PM240M Power Modules - minimum resistance for braking resistors
Frame
size
Rated output
power (kW)
Rated output
current (A)
Article number
Minimum resist‐
ance for braking
resistors
based on High Overload (HO)
FSA
0.37
1.3
6SL3517-1BE11-3AM0
200 Ω
FSA
0.75
2.2
6SL3517-1BE12-3AM0
200 Ω
FSA
1.1
3.1
6SL3517-1BE13-3AM0
200 Ω
FSA
1.5
4.1
6SL3517-1BE14-3AM0
200 Ω
FSB
2.2
5.6
6SL3517-1BE16-3AM0
60 Ω
FSB
3.0
7.3
6SL3517-1BE17-7AM0
60 Ω
FSB
4.0
8.8
6SL3517-1BE21-0AM0
60 Ω
Technical data
11.3 SINAMICS G110M specifications
Distributed converter for SIMOGEAR geared motors
392
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
Содержание SINAMICS G110M
Страница 2: ......
Страница 426: ...Index Distributed converter for SIMOGEAR geared motors 424 Operating Instructions 10 2020 FW V4 7 SP13 A5E31298649B AL ...
Страница 427: ......