Bit Meaning
Explanation
Signal interconnec‐
tion in the converter
1)
Telegram 350
4
1 = DDS selection bit 0
Changes over between settings
for different motors (drive data
sets).
p0820 = r2093.4
5
1 = DDS selection bit 1
p0821 = r2093.5
6
Not used
7
Not used
8
1 = technology controller enable
--
p2200[0] = r2093.8
9
1 = enable DC braking
--
p1230[0] = r2093.9
10 Not used
11 1 = Enable droop
Enable or inhibit speed control‐
ler droop.
p1492[0] = r2093.11
12 1 = torque control active
0 = speed control active
Changes over the control mode
for vector control.
p1501[0] = r2093.12
13 1 = no external fault
0 = external fault is active (F07860)
--
p2106[0] = r2093.13
14 Not used
15 1 = CDS bit 1
Changes over between settings
for different operation interfaces
(command data sets).
p0811[0] = r2093.15
1)
If you switch from telegram 350 to a different one, then the converter sets all interconnections p1020,
… to "0". Exception: p2106 = 1.