Parameter
Number
Name
Factory setting
p1055[C]
BI: Jogging bit 0
Depending on the
converter
p1056[C]
BI: Jogging bit 1
Depending on the
converter
p1058[D]
Jogging 1 speed setpoint
150 rpm
p1059[D]
Jogging 2 speed setpoint
-150 rpm
p1082[D]
Maximum speed
1500 rpm
p1110[C]
BI: Inhibit negative direction
Depending on the
converter
p1111[C]
BI: Inhibit positive direction
0
p1113[C]
BI: Setpoint inversion
0
p1120[D]
Ramp-function generator ramp-up time
Depending on the
converter
p1121[D]
Ramp-function generator ramp-down time
Depending on the
converter
Advanced commissioning
8.8 Jogging
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL