8.5.2
Two-wire control, clockwise/counterclockwise rotation 1
Function description
&ORFNZLVH
&RXQWHUFORFNZLVH
212))
&RXQWHUFORFNZLVH
212))
&ORFNZLVH
6SHHGVHWSRLQW
&RPPDQGKDVQRHIIHFW
W
W
W
6723
6723
6723
Figure 8-6
Two-wire control, clockwise/counterclockwise rotation 1
Commands "ON/OFF1 clockwise rotation" and "ON/OFF1 counter-clockwise rotation" switch on
the motor - and simultaneously select a direction of rotation. The converter only accepts a new
command when the motor is at a standstill.
Table 8-11
Function table
ON/OFF1 clockwise rota‐
tion
ON/OFF1 counter-clock‐
wise rotation
Function
0
0
The motor stops.
1
0
Clockwise motor rotation.
0
1
Counter-clockwise motor rotation.
1
1
The motor direction of rotation is defined by
the command that first reaches state "1".
Examples
Table 8-12
Two-wire control and setting the assignment of the digital inputs
Parameter
Description
p3334 = 1
2/3 wire control selection
1: Two-wire control, clockwise/counterclockwise rotation 1
p3330[C] = 722.0
BI: 2/3 wire control command 1 (ON/OFF1 clockwise rotation)
Command is received via digital input 0
p3331[C] = 722.1
BI: 2/3 wire control command 2 (ON/OFF1 counter-clockwise rotation)
Command is received via digital input 1
Advanced commissioning
8.5 Controlling clockwise and counter-clockwise rotation via digital inputs
Distributed converter for SIMOGEAR geared motors
174
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL