SIJECT OP15B Screens
SIJECT 15/16 Operation Manual June, 2003
3-26
3.1.10 Service screen
Fig 3-22
Service screen 1 – parameter setting
Operating sequences
Press this key to enter the service screen. See Fig 3-22 Service screen 1
--- parameter setting.
On service screen, input password 2 (2000) before any parameter
setting. Then, confirm your entry by “Enter” key.
Parameter setting
See Fig. 3-22 Service screen 1 --- parameter setting.
Carriage retract mode (CarRetMod)
-
Carriage retract can be set as
position mode
or
time mode
.
Photo sensor mode (CycSenNSTD)
-
Photo sensor can be set as
normally
open mode
or
normally close mode
.
Lubrication error (LubErrNSTD)
-
Contactor in alarm circuit can be
set as
normally open mode
or
normally close mode
.
Fast mold open (FastMldOpn)
-
It can be set as
normal mode
or
special mode
.
Motor protection (MotStrPro)
-
Motor protection can be selected, i.e.,
if there is delay time during motor star triangle startup. Motor protection
can also be deselected.
Special function 1 (SpecSel 1)
-
Spare.
Special function 2 (SpecSel 2)
-
Spare.
Number of screw cams (ScrewCam)
-
The cam numbers set on the
screw during screw speed measurement. Range: 1
~
255.