SIJECT 15/16 Operation Manual
3-35
Fig 3-29
Service screen 2.3 – temperature setting
Temperature setting
On service screen 1, press softkey F2
to enter service screen 2 --
- linear scale setting. Then, press softkey F4
so as to enter
temperature setting screen. Temperature channel can be set from 1 to 5,
and temperature can be set accordingly.
Temperature Tolerance Plus
--- set the tolerance plus for each
temperature channel.
Temperature Tolerance Minus
--- set the tolerance minus for each
temperature channel.
Oil Upper
--- set the upper limit of hydraulic oil temperature.
Oil Lower
--- set the lower limit of hydraulic oil temperature.
Temperature Compensation
--- set the temperature compensation. The
system has been set the compensation before delivery, and it is
unnecessary for users to set it again.
Nozzle Mode
--- two modes are available, it can be assigned as close-
loop or open-loop.
Channel 1
--- select or deselect
Channel 2
--- select or deselect
Channel 3
--- select or deselect
Channel 4
--- select or deselect
Channel 5
--- select or deselect
Oil Temperature Alarm
--- If oil temperature alarm is selected: when the
upper/lower limit of oil temperature has been set, there is no alarm if oil
temperature is within the specification and alarm occurs if it is out of
specification.