SIJECT OP15B Screens
SIJECT 15/16 Operation Manual June, 2003
3-28
Linear Scale mold:
Switch
--- Proximity switch signal. When mold close is at position, the
box will backlight, showing the reference point of linear scale.
Reference point
--- setting value. Mold lock end should be the reference
of linear scale.
Length
--- setting value. The length of linear scale can be set here,
ranged from 1
~
6553mm.
Actual value
--- displayed value. Display the actual value of linear scale.
Current value
--- displayed value. It is the difference from actual value to
reference point.
Linear scale injection:
Reference point
--- setting value. Reference point of linear scale can be
set here.
Length
--- setting value. The length of linear scale can be set here,
ranged from 1
~
6553mm.
Actual value
--- displayed value. Display the actual value of linear scale.
Current value
--- displayed value. It is the difference from actual value to
reference point.
Linear scale ejector:
Switch
--- Proximity switch signal. When ejector retract is at position, the
box will backlight, showing the reference point of linear scale.
Reference point
--- setting value. Ejector retract end should be the
reference of linear scale.
Length
--- setting value. The length of linear scale can be set here,
ranged from 1
~
6553mm.
Actual value
--- displayed value. Display the actual value of linear scale.
Current value
--- displayed value. It is the difference from actual value to
reference point.
Linear scale ejector
--- Linear scale ejector can be selected or
deselected here.